background image

NI 1357/1358/1359 Kit Installation Guide

10

ni.com

c.

Select the 

Channels 

tab.

d.

Designate source channels for the topology selected in the 

Terminal Block/Topology

 tab. Notice that you can set different 

source channels for each topology.

e.

Designate reserved channels for routing. Notice that you can 
reserve different channels for routing in each topology.

f.

Click 

OK

 to accept the changes.

8.

To configure additional SCXI switch modules, repeat steps 6 and 7.

9.

If necessary, select the 

Chassis

 tab to modify chassis settings.

10. Click 

OK

 to accept and save the settings for the chassis.

Note

You cannot save the chassis configuration until after you enter the switch module 

information. A message at the top of the SCXI Chassis Configuration dialog box displays 
the configuration status. If a warning appears in the message box, you can save the 
configuration. If an error appears in the message box, you cannot save the configuration.

11. To test the configuration, right-click the chassis name listed under 

Devices and Interfaces

, and select 

Test

.

After the test, a message indicates successful verification of the 
configuration or if an error occurred. If an error occurs, refer to 

ni.com/support/install

 for troubleshooting information.

Specifications

Maximum Voltage

Terminal to earth ....................................300 V

rms 

or VDC

Terminal to terminal ...............................300 V

rms

 or VDC

Maximum Current

Maximum current (per channel) .............2 ADC, 2 AAC

Bus Interface

USB specification ...................................USB 2.0 full-speed

USB bus speed........................................12 Mb/s

USB Power Requirements

5 VDC.....................................................25 mA typical, 100 mA max

Содержание SCXI USB-1357

Страница 1: ...USB 1357...

Страница 2: ...ge signals among switches Introduction Note Both SCXI and USB kits connect to an SCXI switch with a 10 pin rear connector Refer to the NI Switches Getting Started Guide to determine the switches and s...

Страница 3: ...I DAQ 7 4 or later before you install the NI 1357 1358 1359 kit Complete the following steps to install the NI 1357 1358 1359 kit 1 Power off and unplug the SCXI chassis Follow proper electrostatic di...

Страница 4: ...the switch controller Refer to Figures 2 and 3 to verify the connector positions on the NI 1359 Figure 2 2 Slot HVAB Backplane Adapter Connectors Figure 3 8 Slot HVAB Backplane Adapter Connectors 1 HV...

Страница 5: ...ts Connect one end of the SH9MD AUX cable to the NI SCXI 1359 cable adapter and the other end to the NI 4021 4060 407x switch controller as shown in Figure 4 Figure 4 Cabling an NI 4021 4060 407x Swit...

Страница 6: ...configure the switch module Multichassis Configuration Complete the following steps to create a multichassis switch configuration 1 Complete the Installing the Kit section steps 1 through 7 for each c...

Страница 7: ...of the HVAB backplane adapter and the other end to the NI 4021 4060 407x switch controller b Using another SH9MD AUX cable connect the AUX OUT of the HVAB backplane adapter on the first chassis to th...

Страница 8: ...ure SCXI switch modules cabled to an NI SCXI 1357 1358 1359 kit proceed directly to step 4 to create a new SCXI chassis If you are using NI DAQmx to configure SCXI switch modules cabled to an NI USB 1...

Страница 9: ...MAX detects only one communicating device this device is selected as the chassis communicator by default and the listbox is dimmed b SCXI kits only Select the module slot connected to the chassis com...

Страница 10: ...it the default name click the Device Identifier textbox and enter a unique alphanumeric ID for the switch module c If you are using a connected accessory such as a terminal block select it from the Ac...

Страница 11: ...witch module information A message at the top of the SCXI Chassis Configuration dialog box displays the configuration status If a warning appears in the message box you can save the configuration If a...

Страница 12: ...NI SCXI 1129 150 V CAT I Example 2 NI SCXI 1000 chassis NI SCXI 1359 2 slot backplane adapter behind Slots 3 and 4 NI SCXI 1127 300 V CAT II in Slot 4 NI SCXI 1129 150 V CAT I in Slot 2 The NI SCXI 11...

Страница 13: ...1 UL 61010 1 CAN CSA C22 2 No 61010 1 Note For UL and other safety certifications refer to the product label or visit ni com certification search by model number or product line and click the appropr...

Отзывы: