Appendix A
Specifications
©
National Instruments Corporation
A-3
Operating Environment
NI PXIe-8106
Ambient temperature range ............ 5 to 50 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
high temperature limit.)
NI PXIe-8106
Extended Temperature Option
Ambient temperature range ............ 0 to 55 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
low temperature limit and
MIL-PRF-28800F Class 2
high temperature limit.)
Relative humidity range ......................... 10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution
The operating temperature must not be exceeded, even when used in a chassis
with a higher temperature range.
Storage Environment
NI PXIe-8106
Ambient temperature range ............ –40 to 65 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3
low temperature limit.)
NI PXIe-8106
Extended Temperature Option
Ambient temperature range ............ –40 to 70 °C
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)