National Instruments PXIe-8106 Скачать руководство пользователя страница 4

 

Important Information

Warranty

The NI PXIe-8106 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced 
by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the 
warranty period. This warranty includes parts and labor. 

The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in 
materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. National Instruments 
will, at its option, repair or replace software media that do not execute programming instructions if National Instruments receives notice of such defects 
during the warranty period. National Instruments does not warrant that the operation of the software shall be uninterrupted or error free.

A Return Material Authorization (RMA) number must be obtained from the factory and clearly marked on the outside of the package before any 
equipment will be accepted for warranty work. National Instruments will pay the shipping costs of returning to the owner parts which are covered by 
warranty.

National Instruments believes that the information in this document is accurate. The document has been carefully reviewed for technical accuracy. In 
the event that technical or typographical errors exist, National Instruments reserves the right to make changes to subsequent editions of this document 
without prior notice to holders of this edition. The reader should consult National Instruments if errors are suspected. In no event shall National 
Instruments be liable for any damages arising out of or related to this document or the information contained in it.

E

XCEPT

 

AS

 

SPECIFIED

 

HEREIN

, N

ATIONAL

 I

NSTRUMENTS

 

MAKES

 

NO

 

WARRANTIES

EXPRESS

 

OR

 

IMPLIED

AND

 

SPECIFICALLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

OF

 

MERCHANTABILITY

 

OR

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

. C

USTOMER

S

 

RIGHT

 

TO

 

RECOVER

 

DAMAGES

 

CAUSED

 

BY

 

FAULT

 

OR

 

NEGLIGENCE

 

ON

 

THE

 

PART

 

OF

 N

ATIONAL

 

I

NSTRUMENTS

 

SHALL

 

BE

 

LIMITED

 

TO

 

THE

 

AMOUNT

 

THERETOFORE

 

PAID

 

BY

 

THE

 

CUSTOMER

. N

ATIONAL

 I

NSTRUMENTS

 

WILL

 

NOT

 

BE

 

LIABLE

 

FOR

 

DAMAGES

 

RESULTING

 

FROM

 

LOSS

 

OF

 

DATA

PROFITS

USE

 

OF

 

PRODUCTS

OR

 

INCIDENTAL

 

OR

 

CONSEQUENTIAL

 

DAMAGES

EVEN

 

IF

 

ADVISED

 

OF

 

THE

 

POSSIBILITY

 

THEREOF

. This limitation of 

the liability of National Instruments will apply regardless of the form of action, whether in contract or tort, including negligence. Any action against 
National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in 
performance due to causes beyond its reasonable control. The warranty provided herein does not cover damages, defects, malfunctions, or service 
failures caused by owner’s failure to follow the National Instruments installation, operation, or maintenance instructions; owner’s modification of the 
product; owner’s abuse, misuse, or negligent acts; and power failure or surges, fire, flood, accident, actions of third parties, or other events outside 
reasonable control.

Copyright

Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or mechanical, including photocopying, 
recording, storing in an information retrieval system, or translating, in whole or in part, without the prior written consent of National 
Instruments Corporation.

National Instruments respects the intellectual property of others, and we ask our users to do the same. NI software is protected by copyright and other 
intellectual property laws. Where NI software may be used to reproduce software or other materials belonging to others, you may use NI software only 
to reproduce materials that you may reproduce in accordance with the terms of any applicable license or other legal restriction.

Trademarks

National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the 

Terms of Use

 section 

on

ni.com/legal

 for more information about National Instruments trademarks.

The ExpressCard

®

 word mark and logos are owned by PCMCIA and any use of such marks by National Instruments is under license. Other product 

and company names mentioned herein are trademarks or trade names of their respective companies.

Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no agency, 
partnership, or joint-venture relationship with National Instruments.

Patents

For patents covering National Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, 

the

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

.

WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

(1) NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL OF 
RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN 
ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT 
INJURY TO A HUMAN.

(2) IN ANY APPLICATION, INCLUDING THE ABOVE, RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE 
IMPAIRED BY ADVERSE FACTORS, INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY, 
COMPUTER HARDWARE MALFUNCTIONS, COMPUTER OPERATING SYSTEM SOFTWARE FITNESS, FITNESS OF COMPILERS 
AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION, INSTALLATION ERRORS, SOFTWARE AND HARDWARE 
COMPATIBILITY PROBLEMS, MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL DEVICES, 
TRANSIENT FAILURES OF ELECTRONIC SYSTEMS (HARDWARE AND/OR SOFTWARE), UNANTICIPATED USES OR MISUSES, OR 
ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER (ADVERSE FACTORS SUCH AS THESE ARE HEREAFTER 
COLLECTIVELY TERMED “SYSTEM FAILURES”). ANY APPLICATION WHERE A SYSTEM FAILURE WOULD CREATE A RISK OF 
HARM TO PROPERTY OR PERSONS (INCLUDING THE RISK OF BODILY INJURY AND DEATH) SHOULD NOT BE RELIANT SOLELY 
UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE. TO AVOID DAMAGE, INJURY, OR DEATH, 
THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO PROTECT AGAINST SYSTEM FAILURES, 
INCLUDING BUT NOT LIMITED TO BACK-UP OR SHUT DOWN MECHANISMS. BECAUSE EACH END-USER SYSTEM IS 
CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS' TESTING PLATFORMS AND BECAUSE A USER OR APPLICATION 
DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT 
EVALUATED OR CONTEMPLATED BY NATIONAL INSTRUMENTS, THE USER OR APPLICATION DESIGNER IS ULTIMATELY 
RESPONSIBLE FOR VERIFYING AND VALIDATING THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER 
NATIONAL INSTRUMENTS PRODUCTS ARE INCORPORATED IN A SYSTEM OR APPLICATION, INCLUDING, WITHOUT 
LIMITATION, THE APPROPRIATE DESIGN, PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION.

Содержание PXIe-8106

Страница 1: ...PXI 8221...

Страница 2: ...PXI Express NI PXIe 8106 User Manual NI PXIe 8106 User Manual December 2008 372095B 01...

Страница 3: ...banon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 328 90 10 Portugal 351 210 311 210 Russia...

Страница 4: ...whole or in part without the prior written consent of National Instruments Corporation National Instruments respects the intellectual property of others and we ask our users to do the same NI software...

Страница 5: ...iguration Installing the NI PXIe 8106 2 1 How to Remove the Controller from the PXI Express Chassis 2 3 BIOS Setup 2 4 Entering BIOS Setup 2 4 Main Setup Menu 2 5 Advanced Setup Menu 2 6 Integrated Pe...

Страница 6: ...iversal Serial Bus 3 9 Trigger 3 10 GPIB IEEE 488 2 3 11 ExpressCard 34 Slot 3 13 Front Panel Features 3 15 Data Storage 3 15 Chapter 4 Common Configuration Questions General Questions 4 1 Boot Option...

Страница 7: ...own the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a note which alerts you to important information This icon denotes a caution which advises yo...

Страница 8: ...anual PICMG EXP 0 R1 0 CompactPCI Express Specification PCI Industrial Computers Manufacturers Group IEEE Standard P1284 1 1997 C MM Standard for Information Technology for Transport Independent Print...

Страница 9: ...ss maximizes both hardware and software compatibility with PXI modules PXI Express hybrid slots deliver both PCI and PCI Express signaling to accept devices that use PXI communication and triggering o...

Страница 10: ...integrates standard I O features in a single unit by using state of the art packaging Combining an NI PXIe 8106 embedded controller with a PXI Express compatible chassis such as the PXIe 1062Q result...

Страница 11: ...he Chipset GMCH connects to the CPU DDR2 SDRAM video and Ethernet The SMB to PXI Trigger provides a routable connection of the PXI Express triggers to from the SMB on the front panel Chipset I O Contr...

Страница 12: ...e GPIB block contains the GPIB interface The ExpressCard 34 slot accommodates an ExpressCard 34 module National Instruments Software National Instruments has developed several software tools you can u...

Страница 13: ...DAQ products Features available include analog input A D conversion buffered data acquisition high speed A D conversion analog output D A conversion waveform generation digital I O counter timer oper...

Страница 14: ...For information on writing your own PXI instrument driver with NI VISA refer to the NI VISA Getting Started Manual and the readme txt file in the NI VISA directory For more information visit ni com v...

Страница 15: ...ific instructions and warnings 1 Plug in your chassis before installing the NI PXIe 8106 The power cord grounds the chassis and protects it from electrical damage while you install the module Caution...

Страница 16: ...slot Caution Do not raise the injector ejector handle as you insert the NI PXIe 8106 The module will not insert properly unless the handle is in its downward position so that it does not interfere wi...

Страница 17: ...itor to the DVI connector 12 Connect devices to ports as required by your system configuration 13 Power on the chassis 14 Verify that the controller boots If the controller does not boot refer to the...

Страница 18: ...em CMOS section In general do not change a setting unless you are absolutely certain what it does Entering BIOS Setup To start the BIOS setup utility complete the following steps 1 Power on or reboot...

Страница 19: ...ror When Disabled the BIOS allows booting without a keyboard If you are using a USB keyboard you may attach it at any time during the powered up state To use this controller in a headless mode you mus...

Страница 20: ...reboot This is rarely necessary Integrated Peripherals Use this setting to bring up the Integrated Peripherals submenu Refer to the Integrated Peripherals Submenu section for more information Quick B...

Страница 21: ...lt is Auto which places COM1 at 0x3F8 IRQ 4 Parallel Port Use this setting to enable or disable LPT1 You also can change this setting to Enabled and modify the base address IRQ level and ISA Direct Me...

Страница 22: ...S prioritizes video controllers when external video cards are present in the system During POST only one device can act as the video display device When set to Enabled the BIOS allows the integrated g...

Страница 23: ...are necessary and may lead to unpredictable behavior APIC Routing This setting controls whether the APIC subsystem is enabled or disabled Select Enabled to initialize the IOAPIC Select Disabled to us...

Страница 24: ...that access the hard disk directly The default is No Boot Setup Menu This screen displays the boot order of devices associated with the controller The BIOS proceeds down the Boot priority order list...

Страница 25: ...their factory defaults This may produce undesirable behavior and in heavily customized cases may cause the controller to malfunction or fail to boot Discard Changes Any changes made to BIOS settings d...

Страница 26: ...a directory called images in its root that contains software and soft copies of manuals for the peripherals The directory structure under the images directory is logically organized into several level...

Страница 27: ...s needed to prevent two resources from connecting to the same trigger line resulting in the trigger being double driven and possibly damaging the hardware At the time of this manual s publication this...

Страница 28: ...unidentified PXI chassis in the PXI System tree right click on the chassis and select the appropriate chassis model through the Identify As submenu Further expanding the PXI System branch shows all de...

Страница 29: ...ng the SO DIMMs To upgrade the RAM remove the NI PXIe 8106 from the PXI Express chassis To optimize both memory capacity and system performance use the same size and speed memory module in each of the...

Страница 30: ...portion of your hard drive allowing you to restore your controller without additional media The NI PXIe 8106 controller also ships with an OS Recovery CD that allows you to reinstall your operating sy...

Страница 31: ...ou want to keep Installing an OS NI PXIe 8106 controllers include a preinstalled OS In some cases you may want to install a different OS When doing so consider the following guidelines Installing from...

Страница 32: ...ted in its connector The connector has an automatic eject mechanism If you insert the card and it is ejected simply re insert the card until it is seated If you encounter too much resistance do not fo...

Страница 33: ...Description Video DVI I 24 pin DSUB Intel Graphics Media Accelerator Serial COM1 9 pin DSUB 16550 RS 232 serial port Ethernet LAN RJ45 10 100 1000 Ethernet connection Parallel Parallel Port 36 pin cha...

Страница 34: ...of the NI PXIe 8106 Dimensions are in inches millimeters Figure 3 1 NI PXIe 8106 Front Panel Layout and Dimensions 1 997 50 72 2 221 56 41 2 328 59 13 2 847 72 31 340 8 64 4 393 111 58 3 840 97 53 3...

Страница 35: ...the DVI connector on the NI PXIe 8106 Table 3 2 lists and describes the DVI connector signals Figure 3 2 DVI Connector Location and Pinout Table 3 2 DVI I Connector Signals Pin Signal Name 1 TMDS Data...

Страница 36: ...4 5 V Power 15 Ground for 5 V 16 Hot Plug Detect 17 TMDS Data0 18 TMDSData0 19 TMDS Data0 5 Shield 20 Reserved 21 Reserved 22 TMDS Clock Shield 23 TMDS Clock 24 TMDS Clock C1 Analog Red C2 Analog Gree...

Страница 37: ...AMP manufactures a serial port mating connector part number 745491 5 Figure 3 3 COM1 Connector Location and Pinout Note The pound symbol indicates an active low signal Table 3 3 COM1 Connector Signals...

Страница 38: ...connector signals AMP manufactures a mating connector part number 554739 1 Figure 3 4 Ethernet Connector Location and Pinout Note The Ethernet controller can perform an automatic crossover thus elimi...

Страница 39: ...National Instruments part number 777169 01 Figure 3 5 Parallel Port Connector Location and Pinout Table 3 5 10 100 1000 LAN Connector LED States LED Color LED State Condition Top Green Off LAN link is...

Страница 40: ...ame Signal Description 1 BUSY Device Busy 2 SLCT Select 3 ACK Acknowledge 4 FAULT ERROR Fault 5 PAPEREND Paper End 6 PD0 Data Bit 0 7 PD1 Data Bit 1 8 PD 2 Data Bit 2 9 PD3 Data Bit 3 10 PD4 Data Bit...

Страница 41: ...the Universal Serial Bus USB connector on the NI PXIe 8106 Each controller has 4 USB ports on the front panel Table 3 7 lists and describes the USB connector signals Figure 3 6 USB Connector Location...

Страница 42: ...r routing PXI triggers to or from the backplane trigger bus Figure 3 7 shows the TRIG connector location on the NI PXIe 8106 Table 3 8 lists and describes the trigger connector signals Figure 3 7 TRIG...

Страница 43: ...3 9 lists and describes the GPIB connector signals ITT Canon manufactures a GPIB mating connector part number MDSM 25SC Z11 V51 Figure 3 8 GPIB Connector Location and Pinout Table 3 9 GPIB Connector...

Страница 44: ...al 8 NDAC Not Data Accepted 9 IFC Interface Clear 10 SRQ Service Request 11 ATN Attention 12 SHIELD Chassis ground 13 DIO5 Data Bit 5 14 DIO6 Data Bit 6 15 DIO7 Data Bit 7 16 DIO8 Data Bit 8 17 REN Re...

Страница 45: ...location and pinouts for the ExpressCard 34 slot on the NI PXIe 8106 Table 3 10 lists and describes the ExpressCard connector signals Figure 3 9 ExpressCard 34 Slot Location and Pinout Table 3 10 Expr...

Страница 46: ...r 13 PERST PE Reset 14 3 3V Power 15 3 3V Power 16 CLKREQ Clock Request 17 CPPE PE Presence 18 REFCLK Reference Clock 19 REFCLK Reference Clock 20 GND Ground 21 PERn0 PE Data Receive 22 PERp0 PE Data...

Страница 47: ...teady PXI and onboard power is on and within regulation limits BLINKING One of the onboard power supplies is operating outside of the normal limits OFF The controller is powered off The DRIVE LED indi...

Страница 48: ...ove my controller or disconnect power The NI PXIe 8106 controller Ethernet device remains powered even after shutdown It is safe to remove your controller or disconnect power How do I check the config...

Страница 49: ...oot from these devices There are two methods Enter the BIOS setup by rebooting the controller and pressing Delete during the memory tests Select the Boot menu You will see a list of all bootable devic...

Страница 50: ...pter Parallel port adapter cables part number 777169 01 are available through the online catalog at ni com products Software Driver Installation How do I install or reinstall the video driver Refer to...

Страница 51: ...y You can change the amount of installed RAM on the NI PXIe 8106 by upgrading the DDR2 SO DIMMs To upgrade the RAM remove the NI PXIe 8106 from the PXI chassis To optimize both memory capacity and sys...

Страница 52: ...nstruments software is available from ni com downloads For peripheral drivers refer to KnowledgeBase 3H3COSD8 at ni com My NI PXIe 8106 does not have an internal floppy drive Is there a way to use an...

Страница 53: ...er on the front panel For details refer to the PXI Express Features section of Chapter 2 Installation and Configuration Why doesn t the NI PXIe 8106 work with the PXI 8220 or PXI 8221 The serialized I...

Страница 54: ...onsulting National Instruments technical support What has changed about the system Did you recently move the system Was there electrical storm activity Did you recently add a new module memory chip or...

Страница 55: ...y have defaulted to the CRT connector being disabled Press Ctrl Alt F1 to re enable the CRT in Windows For additional information refer to KnowledgeBase 3OHCFRD8 at ni com support My system boots fine...

Страница 56: ...s 2 3 as shown in Figure 5 1 4 Wait one second Move the jumper back to pins 1 2 5 Reinstall the controller in the chassis Caution Do not leave the jumper on pins 2 3 Doing so decreases battery life Al...

Страница 57: ...andard 2 GB Maximum Hard Drive 30 GB Serial ATA minimum Ethernet 10 100 1000 BaseTX PXI Express 4 Link Configuration Supports 3 x4 links and 1 x1 link PXI Express 2 Link Configuration Supports 2 x4 li...

Страница 58: ...ith PXI Express Specification 1 0 Weight 0 97 Kg 2 14 lb typical Environment Maximum altitude 2 000 m 800 mbar at 25 C ambient temperature Pollution Degree 2 Indoor use only Caution Clean the NI PXIe...

Страница 59: ...s 3 low temperature limit and MIL PRF 28800F Class 2 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Caution The operating temperature mu...

Страница 60: ...00F Class 3 Note Specifications are subject to change without notice Safety This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurem...

Страница 61: ...nformity DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product line and click...

Страница 62: ...environment weee htm Battery Replacement and Disposal This device contains a long life coin cell battery If you need to replace it use the Return Material Authorization RMA process or contact an autho...

Страница 63: ...Service Program Membership This program entitles members to direct access to NI Applications Engineers via phone and email for one to one technical support as well as exclusive access to on demand tr...

Страница 64: ...mpatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If you searched ni com and could not find the answers you need contact your local office or...

Страница 65: ...s Ohms Percent A A Amperes AC Alternating Current B B Bytes backplane An assembly typically a printed circuit board with connectors and signal paths that bus the connector pins BIOS Basic Input Output...

Страница 66: ...mance of PCI as well as the small size and ruggedness of a rack mount system D DC Direct Current DDR Double Data Rate DMA Direct Memory Access A method by which data is transferred between devices and...

Страница 67: ...on levels in a random vibration test profile H Hz Hertz Cycles per second I I O Input Output The techniques media and devices used to achieve communication between machines and users IDE Integrated Dr...

Страница 68: ...ications link LED Light emitting diode M m Meters master A functional part of a PXI device that initiates data transfers on the PXI backplane A transfer can be either a read or a write MB Megabytes of...

Страница 69: ...hat meet the high performance requirements of instrumentation applications by providing triggering local buses and system clock capabilities PXI Express also offers two way interoperability with Compa...

Страница 70: ...Glossary NI PXIe 8106 User Manual G 6 ni com U USB Universal Serial Bus V V Volts VGA Video Graphics Array The minimum video display standard for all PCs W W Watts...

Страница 71: ...ntents figure 2 12 5 3 setting back to default 5 2 COM1 connector connector locations and pinout figure 3 5 connector signals table 3 5 common configuration questions boot options 4 2 cables and conne...

Страница 72: ...electromagnetic compatibility A 4 entering the BIOS setup 2 4 environmental management specifications A 5 battery replacement and disposal A 6 WEEE information A 6 Ethernet connector 3 1 location and...

Страница 73: ...ew caps figure 2 2 installing an OS from USB CD DVD ROM 2 17 overview 2 17 installing the GPIB driver 4 3 installing the video driver 4 3 instrument drivers NI resources B 1 integrated peripherals BIO...

Страница 74: ...om a PXI Express chassis 2 3 software 1 4 specifications A 1 troubleshooting 5 1 upgrading RAM 2 15 4 4 NI support and services B 1 NI DAQmx 1 5 NI VISA 1 6 O operating environment specifications A 2...

Страница 75: ...1 specifications A 1 CE compliance A 5 electrical A 2 electromagnetic compatibility A 4 environmental management A 5 battery replacement and disposal A 6 WEEE information A 6 online product certifica...

Страница 76: ...A location and pinout figure 3 3 overview table 3 1 video 3 1 See also VGA driver installation 4 3 W Web resources B 1 WEEE information A 6 Y Y splitter cable figure 4 3 using mouse and keyboard witho...

Отзывы: