Figure 3.  

Waveform Generation Device Overlay

2.

Apply the label to the inside of the top cover as shown in Figure 4. 
This label is a pin number to signal name reference. Each overlay has 
an adhesive backing for adhering the overlay to the top cover.

Figure 4.  

Applying the Overlay

PIN#

SIGNAL

PIN#

SIGNAL

PIN#

SIGNAL

68
34
29
33
66
24
65
31
56
57
23
22
54

8

46
50
42
18

5

37

2
1

28
61
59
62
25
58
27
21
20
55
16
48
35
11
43
41

6
4

NC

AO GND
AO GND

NC

AOGND
AOGND

DAC7OUT

AOGND
AOGND

DAC2OUT

AOGND

DAC0OUT

AOGND

+5V

NC

DGND

PFI3

DGND

PFI6
PFI8

GPCTR0_OUT

FREQ_OUT

DAC5OUT

AO GND
AO GND

NC

DAC3OUT

AOGND
AOGND

DAC1OUT

EXTREF

AOGND

DIO6
DIO7

DGND

PFI0
PFI2
PFI4
PFI5

DGND

30
63
67
60
26
64
32
19
52
17
53

9

51
49
47
45
10
14
40
38

3

36

DAC6 OUT

AOGND
AOGND

DAC4OUT

AOGND
AOGND
AOGND

DIO4
DIO0
DIO1

DGND
DGND

DIO5
DIO2
DIO3

EXTSTROBE

PFI1

+5V

GPCTR1_OUT

PFI7
PFI9

DGND

PIN#

SIGNAL

PIN#

SIGNAL

PIN#

SIGNAL

68

34

29

33

66

24

65

31

56

57

23

22

54

8

46

50

42

18

5

37

2

1

28

61

59

62

25

58

27

21

20

55

16

48

35

11

43

41

6

4

NC

AO GND

AO GNDNC

AOGND

AOGND

DAC7OUT

AOGND

AOGND

DAC2OUT

AOGND

DAC0OUT

AOGND+5V

NC

DGND

PFI3

DGND

PFI6

PFI8

GPCTR0_OUT

FREQ_OUT

DAC5OUT

AO GND

AO GNDNC

DAC3OUT

AOGND

AOGND

DAC1OUT

EXTREF

AOGNDDIO6

DIO7

DGND

PFI0

PFI2

PFI4

PFI5

DGND

30

63

67

60

26

64

32

19

52

17

53

9

51

49

47

45

10

14

40

38

3

36

DAC6 OUT

AOGND

AOGND

DAC4OUT

AOGND

AOGND

AOGNDDIO4

DIO0

DIO1

DGND

DGND

DIO5

DIO2

DIO3

EXTSTROBE

PFI1

+5V
GPCTR1_OUT

PFI7

PFI9

DGND

Содержание PXI TB-2705

Страница 1: ...terminal block assembly connects directly to the front panel of National Instruments E Series and waveform generation devices eliminating the need for an external cable The TB 2705 allows you to easil...

Страница 2: ...aution which advises you of precautions to take to avoid injury data loss or a system crash italic Italic text denotes variables emphasis a cross reference or an introduction to a key concept This fon...

Страница 3: ...the terminal block National Instruments is not liable for any damages or injuries resulting from incorrect signal connections Clean the module and accessories by brushing off light dust with a soft no...

Страница 4: ...he analog output voltages are referenced to these terminals All three ground references AIGND AOGND and DGND are connected together on your E Series device DGND Digital Ground These pins supply the re...

Страница 5: ...s is the TRIG1 signal In posttrigger data acquisition sequences a low to high transition indicates the initiation of the acquisition sequence In pretrigger applications a low to high transition indica...

Страница 6: ...date As an input this is one of the PFIs Output As an output this is the UPDATE signal A high to low edge on UPDATE indicates that the analog output primary group is updating PFI6 WFTRIG DGND Input PF...

Страница 7: ...UT DGND Output Frequency Output This output is from the frequency generator output Table 2 TB 2705 Terminal Block Waveform Generation Signal Descriptions Signal Name Reference Direction Description AO...

Страница 8: ...s You cannot use PFI1 as an output PFI2 DGND Input PFI2 As an input this is one of the PFIs You cannot use PFI2 as an output PFI3 GPCTR1_SOURCE DGND Input PFI3 Counter 1 Source As an input this is one...

Страница 9: ...e PFIs You cannot use PFI7 as an output PFI8 GPCTR0_SOURCE DGND Input PFI8 Counter 0 Source As an input this is one of the PFIs Output As an output this is the GPCTR0_SOURCE signal This signal reflect...

Страница 10: ...connect your signals Refer to Figure 1 as you perform the following steps to connect signals to your terminal block Figure 1 TB 2705 Parts Locator Diagram 1 Cover 2 Cover Screws Captive 3 Strain Reli...

Страница 11: ...3 22 54 8 46 50 42 18 5 37 2 1 28 61 59 62 25 58 27 21 20 55 16 48 35 11 43 41 6 4 ACH0 ACH8 AIGND ACH1 ACH9 AIGND ACH2 ACH10 AIGND ACH7 ACH15 DAC0OUT AOGND 5V SCANCLK DGND PFI3 GPCTR1_SOURCE DGND PFI...

Страница 12: ...UT AOGND AOGND AOGND DIO4 DIO0 DIO1 DGND DGND DIO5 DIO2 DIO3 EXTSTROBE PFI1 5V GPCTR1_OUT PFI7 PFI9 DGND P I N S I G N A L P I N S I G N A L P I N S I G N A L 6 8 3 4 2 9 3 3 6 6 2 4 6 5 3 1 5 6 5 7 2...

Страница 13: ...hten or replace the strain relief screws 8 Replace the terminal block cover and tighten the cover screws Installing the Terminal Block Refer to Figure 5 as you perform the following steps to connect t...

Страница 14: ...der that reduces the voltage to within the input range of the DAQ device Input voltages greater than 42 V can damage the TB 2705 any device connected to it and the host computer Overvoltage can also c...

Страница 15: ...ge temperature 20 to 70 C Relative humidity 10 to 90 noncondensing Safety Designed in accordance with IEC61010 01 EN 61010 1 UL 3111 1 and CAN CSA C22 2 No 1010 1 for electrical measuring and testing...

Страница 16: ...nical support resources on our Web site and still cannot find the answers you need contact your local office or National Instruments corporate For telephone support in the United States dial 512 795 8...