Getting Started with the NI PCIe-1433

You

 must

 insulate signal connections for the maximum voltage for which the device is rated. Do 

not

 

exceed the maximum ratings for the device. Remove power from signal lines before connection to or 
disconnection from the device.

Caution

National Instruments measurement products may be classified as either Measurement 

Category I or II. Operate products at or below the Measurement Category level specified in the 
hardware specifications.

Measurement Category

1

: Measurement circuits are subjected to working voltages

2

 and transient 

stresses (overvoltage) from the circuit to which they are connected during measurement or test. 
Measurement Category establishes standardized impulse withstand voltage levels that commonly
occur in electrical distribution systems. The following is a description of Measurement (Installation

3

Categories:

Measurement Category I is for measurements performed on circuits 

not

 directly connected to the 

electrical distribution system referred to as MAINS

4

 voltage. This category is for measurements of 

voltages from specially protected secondary circuits. Such voltage measurements include signal 
levels, special equipment, limited-energy parts of equipment, circuits powered by regulated 
low-voltage sources, and electronics.

Measurement Category II is for measurements performed on circuits directly connected to the 
electrical distribution system. This category refers to local-level electrical distribution, such as
that provided by a standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). Examples of 
Measurement Category II are measurements performed on household appliances, portable tools, 
and similar products.

Measurement Category III is for measurements performed in the building installation at the 
distribution level. This category refers to measurements on hard-wired equipment such as 
equipment in fixed installations, distribution boards, and circuit breakers. Other examples are 
wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, 
and stationary motors with permanent connections to fixed installations.

Unpacking

The NI 1433 ships in an antistatic package to prevent electrostatic discharge from damaging device 
components. To avoid such damage in handling your device, take the following precautions:

1.

Ground yourself using a grounding strap or by touching a grounded object, such as the computer 
chassis.

2.

Touch the antistatic package to a metal part of the computer chassis before removing the device 
from the package.

Caution

Never

 touch the exposed pins of connectors.

3.

Remove the device from the package and inspect it for loose components or any other signs of 
damage. Notify National Instruments if the device appears damaged in any way. Do 

not

 install

a damaged device in the computer.

Store the NI 1433 in the antistatic package when not in use.

1   

Measurement Categories as defined in electrical safety standard IEC 61010-1.

2   

Working voltage is the highest rms value of an AC or DC voltage that can occur across any particular insulation.

3   

Measurement Category is also referred to as Installation Category.

4   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the 
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Содержание PCIe-1433

Страница 1: ...Computer running Microsoft Windows 7 32 bit and 64 bit versions Vista 32 bit and 64 bit versions XP 2000 with at least one available x4 or larger PCIe slot NI IMAQ 4 4 or later driver software which i...

Страница 2: ...st even when the equipment is turned off To avoid a shock hazard do not perform procedures involving cover or shield removal unless you are qualified to do so Disconnect all field power prior to remov...

Страница 3: ...rement Category II are measurements performed on household appliances portable tools and similar products Measurement Category III is for measurements performed in the building installation at the dis...

Страница 4: ...The NI 1433 will not fit properly into a x1 PCIe slot The NI 1433 will fit into and can be used in a x8 or x16 PCIe slot Using a smaller width device in a larger width slot is called up plugging When...

Страница 5: ...of the particular camera you are using Refer to MAX for information about valid camera attributes for your camera and image acquisition device Many camera files are installed when you install NI IMAQ...

Страница 6: ...and according to the documentation CE Compliance This product meets the essential requirements of applicable European Directives as follows 2006 95 EC Low Voltage Directive safety 2004 108 EC Electrom...

Страница 7: ...to the Vision Builder AI Examples directory Visit the NI Developer Zone at ni com zone for the latest example programs tutorials technical presentations and a community area where you can share ideas...

Страница 8: ...electronic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificat...

Отзывы: