B-12
|
ni.com
Appendix B
Specifications for Legacy Products
Power Requirements
Environment
Maximum altitude
2,000 m
Pollution Degree
2
Indoor use only.
Operating Environment
Ambient temperature range
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage Environment
Ambient temperature range
-40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Storage relative humidity
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Shock and Vibration
Operational shock
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Test profile developed in accordance with
MIL-PRF-28800F.)
Power Rail
Typical Current
Maximum Current
+3.3 V
440 mA
650 mA
+5 V
8 mA
10 mA
+12 V
10 mA
12 mA
-12 V
0 A
0 A
VIO
0 A
1 mA