A-36
|
ni.com
Appendix A
Specifications
MIL-PRF-28800F Class 2 high temperature
limit.)
Operating relative humidity
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage Environment
Ambient temperature range
-40 to 71 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F
Class 3 limits.)
Relative humidity range
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56)
Shock and Vibration
Operational shock
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
Meets MIL-PRF-28800F Class 2 limits.)
Random Vibration
Operating
5 to 500 Hz, 0.3 g
rms
Nonoperating
5 to 500 Hz, 2.4 g
rms
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
Caution
Clean the PXIe-8364 with a soft nonmetallic brush. Make sure that the
device is completely dry and free from contaminants before returning it to service.
Note
For full EMC compliance, operate this device with shielded cabling. In
addition, all covers and filler panels must be installed. To obtain the DoC for this
product, visit
ni.com/certification
, search by model number or product line,
and click the appropriate link in the Certification column.