© National Instruments Corporation
|
B-21
MXI-Express x1 Series User Manual
Storage Environment
Ambient temperature range
-20 to 65 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Nonoperating thermal shock
-20 to 65 °C, 5 shocks
Shock and Vibration
Nonoperating shock
50 g, 11 ms
(Tested in accordance with IEC 60068-2-27.)
Nonoperating vibration sinusoidal
15 g 100 to 2000 Hz
(Tested in accordance with IEC 60068-2-6.)
Nonoperating drop test
2 drops in 3 mutually exclusive axes from 75 cm
onto no-cushioning vinyl tile surface
Safety
This product is designed to meet the requirements of the following standards of safety for
information technology equipment:
•
IEC 60950-1, EN 60950-1
•
UL 60950-1
•
CAN/CSA-C22.2 No. 60950-1
Note
For UL and other safety certifications, refer to the product label or visit
ni.com/certification
, search by model number or product line, and click the
appropriate link in the Certification column.
Electromagnetic Compatibility
Emissions
EN 55011 Class A at 10 m. FCC Part 15A above
1 GHz
Immunity
EN 61326:1997 + A2:2001, Table1
1
CE, C-Tick, and FCC Part 15 (Class A) Compliant
Note
For EMC compliance, operate this device with shielded cabling.
1
In the presence of ESD or surge events, the link may fail. If this happens, the user should reboot the host
computer.