Appendix B
Mounting Information
©
National Instruments Corporation
B-3
NI CVS-1450 Series User Manual
Figure B-3.
Bottom View of the NI CVS-1450 Series with Dimensions
Note
You can ground the NI CVS-1450 device to your mount by connecting a grounding
wire to the grounding lug on the NI CVS-1450 device. Refer to the
section of Chapter 2,
LEDs, DIP Switches, and Connectors
, for more
information about the grounding lug.
Caution
Your installation must meet the following space and cabling clearance
requirements for optimum cooling:
•
Allow 76.2 mm (3.0 in.) on the top and bottom of the NI CVS-1450 device for air
circulation.
•
Allow 50.8 mm (2.0 in.) on the sides of the NI CVS-1450 device for air circulation.
•
Allow enough space in front of the NI CVS-1450 device to connect cables.
62.56 mm
(2.463 in.)
19.79 mm
(0.779 in.)
6-32 UNC
Grounding Lug