Chapter 3
Digital I/O Functionality
NI CVS-1450 Series User Manual
3-6
ni.com
Trigger Polarity
Each pulse generator can be individually configured for rising or falling
edge triggering. Even if multiple pulse generators are using the same
trigger, each can have different polarities.
Figure 3-2 shows the output of a pulse generator configured to look for a
rising edge trigger and output a high pulse with a microsecond width and
delay.
Figure 3-2.
High Pulse with Rising Edge Trigger
Figure 3-3 shows how to create a high and low pulse train with a
microsecond delay and width.
Figure 3-3.
High and Low Pulse Trains
Trigger
Pulse
Delay
Width
Low Pulse Train
High Pulse Train
Delay
Width
Width
Delay
Software
Start