A-2
|
ni.com
Appendix A
Specifications
DC Output
DC current capacity (I
MP
)
Note
Maximum total available power for the NI PXIe-1085 12 GB/s is 791 W.
Maximum total available power for the NI PXIe-1085 24 GB/s is 775 W.
Backplane slot current capacity
Notes
Total system slot current should not exceed 45 A.
PCI V(I/O) pins in PXI-1 peripheral slots and hybrid peripheral slots are connected
to +5 V.
The maximum power dissipated in the system slot should not exceed 140 W.
The maximum power dissipated in a peripheral slot should not exceed 38.25 W.
Voltage
Maximum Current
NI PXIe-10
8
5 12 GB/s
NI PXIe-10
8
5 24 GB/s
+3.3 V
60 A
60 A
+5 V
44 A
49 A
+12 V
62 A
62 A
-12 V
4 A
4 A
5 VAUX
2 A
2 A
Slot
+5 V
V(I/O)
+3.3 V
+12 V
-12 V
5 VAUX
System Controller Slot
15 A
—
15 A
30 A
—
1 A
System Timing Slot
—
—
6 A
4 A
—
1 A
Hybrid Peripheral Slot with
PXI-1 Peripheral
6 A
5 A
6 A
1 A
1 A
—
Hybrid Peripheral Slot with
PXI-5 Peripheral
—
—
6 A
4 A
—
1 A
PXI-1 Peripheral Slot
6 A
11 A
6 A
1 A
1 A
—