10
|
ni.com
|
NI PS-12/13 Power Supply User Manual and Specifications
Figure 4.
NI PS-13 Input Voltage Vs. Output Load
Input Current Inrush Surge
An active inrush limitation circuit limits the input inrush current after input voltage is applied.
The charging current into EMI suppression capacitors is disregarded in the first milliseconds
after power up.
Note
Input current values are typical with Ta = 25 °C, cold start.
NI PS-12
115 VAC....................................................20 A
230 VAC....................................................40 A
NI PS-13
115 VAC....................................................40 A
230 VAC....................................................80 A
Hold-up Time
Note
Hold-up time values are typical with Ta = 25 °C, cold start.
NI PS-12
115 VAC....................................................20 ms
230 VAC....................................................20 ms
NI PS-13
115 VAC....................................................20 ms
230 VAC....................................................20 ms
Convection Cooling
Forced Air Cooling (ventil
a
tion: 1
8
CFM)