Appendix A
Specifications
©
National Instruments Corporation
A-3
MXI-Express Series User Manual
Shock and Vibration
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random Vibration
Operating................................................ 5 to 500 Hz, 0.3 g
rms
Nonoperating.......................................... 5 to 500 Hz, 2.4 g
rms
(Tested in accordance
with IEC-60068-2-64.
Nonoperating test profile
exceeds the requirements of
MIL-PRF-28800F, Class 3.)
NI PCIe-8360
Maximum altitude .................................. 2,000 m
Pollution Degree .................................... 2
Indoor use only
Operating Environment
Ambient temperature range.................... 0 to 40 °C (tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2)
Operating relative humidity ................... 10 to 90%, noncondensing
(tested in accordance with
IEC-60068-2-56)
Storage Environment
Ambient temperature range.................... –20 to 70 °C (tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2)
Storage relative humidity ....................... 5 to 95%, noncondensing
(tested in accordance with
IEC-60068-2-56)