Compliance

Compliance with FCC/Canada Radio Frequency Interference 
Regulations

Determining FCC Class

The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC 
places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations only) 
or Class B (for use in residential or commercial locations). All National Instruments (NI) products are FCC Class A products.

Depending on where it is operated, this Class A product could be subject to restrictions in the FCC rules. (In Canada, the 
Department of Communications (DOC), of Industry Canada, regulates wireless interference in much the same way.) Digital 
electronics emit weak signals during normal operation that can affect radio, television, or other wireless products.

All Class A products display a simple warning statement of one paragraph in length regarding interference and undesired 
operation. The FCC rules have restrictions regarding the locations where FCC Class A products can be operated.

Consult the FCC Web site at 

www.fcc.gov

 for more information.

FCC/DOC Warnings

This equipment generates and uses radio frequency energy and, if not installed and used in strict accordance with the instructions 
in this manual and the CE marking Declaration of Conformity*, may cause interference to radio and television reception. 
Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department 
of Communications (DOC). 

Changes or modifications not expressly approved by NI could void the user’s authority to operate the equipment under the 
FCC Rules.

Class A

Federal Communications Commission

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated 
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the interference 
at their own expense.

Canadian Department of Communications

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Compliance with EU Directives

Users in the European Union (EU) should refer to the Declaration of Conformity (DoC) for information* pertaining to the 
CE marking. Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance 
information. To obtain the DoC for this product, visit 

ni.com/certification

, search by model number or product line, 

and click the appropriate link in the Certification column.

* The CE marking Declaration of Conformity contains important supplementary information and instructions for the user or 

installer.

Содержание NI PCIe-8360

Страница 1: ...TM MXI Express Series User Manual MXI Express Multisystem eXtension Interface for PCI Express Compact PCI and PXI Bus Computers NI PCIe 8360 NI PXI 8360 MXI Express Series User Manual May 2005 371452A...

Страница 2: ...orea 82 02 3451 3400 Lebanon 961 0 1 33 28 28 Malaysia 1800 887710 Mexico 01 800 010 0793 Netherlands 31 0 348 433 466 New Zealand 0800 553 322 Norway 47 0 66 90 76 60 Poland 48 22 3390150 Portugal 35...

Страница 3: ...es fire flood accident actions of third parties or other events outside reasonable control Copyright Under the copyright laws this publication may not be reproduced or transmitted in any form electron...

Страница 4: ...t of Communications DOC Changes or modifications not expressly approved by NI could void the user s authority to operate the equipment under the FCC Rules Class A Federal Communications Commission Thi...

Страница 5: ...Unpacking 1 3 Chapter 2 Hardware Installation Hardware Installation 2 1 Installing an NI PCIe 8360 2 1 Installing an NI PXI 8360 2 3 Cabling 2 4 Powering Up the MXI Express System 2 5 Powering Down t...

Страница 6: ...Contents MXI Express Series User Manual vi ni com Appendix B Common Questions Appendix C Technical Support and Professional Services Glossary Index...

Страница 7: ...ash bold Bold text denotes items that you must select or click in the software such as menu items and dialog box options Bold text also denotes parameter names italic Italic text denotes variables emp...

Страница 8: ...helpful as you read this manual Set Up Your MXI Express System Your computer or chassis documentation PXI Hardware Specification Revision 2 1 PXI Software Specification Revision 2 1 PCI Specification...

Страница 9: ...e installed as a PCI Express card and a PXI card About the MXI Express Series Description and Features MXI Express functions as a cabled PCI Express link of up to 7 m and a PCI Express to PCI bridge W...

Страница 10: ...CompactPCI chassis If multiple PCI Express slots are available in the host PC additional PXI chassis can be connected by installing an NI PCIe 8360 in any available PCI Express slot Figure 1 2 shows...

Страница 11: ...ompliant with the PCI Express Specification Revision 1 0a or later Unpacking Your MXI Express cards are shipped in antistatic packages to prevent electrostatic damage ESD to the devices ESD can damage...

Страница 12: ...hile installing the NI PCIe 8360 The power cord grounds the chassis and protects it from electrical damage while you install the card Caution To protect both yourself and the computer from electrical...

Страница 13: ...connector is resting on the expansion slot receptacle Using slow evenly distributed pressure press the NI PCIe 8360 straight down until it seats in the expansion slot 7 Reinstall the bracket retaining...

Страница 14: ...city that might be on your clothes or body 5 Make sure the injector ejector handle is in its downward position Be sure to remove all connector packaging and protective caps from retaining screws on th...

Страница 15: ...ds The cables have no polarity so either end may be connected to either card Caution Do not remove the cable after the system is powered on Doing so can hang or cause errors in applications communicat...

Страница 16: ...ans that all of the expansion chassis must be turned on before the host PC for the BIOS and OS to correctly configure a MXI Express system Note There are no requirements on how MXI Express expansion c...

Страница 17: ...nsparent to device drivers so no additional software is needed to support using PXI and CompactPCI devices in a chassis connected using MXI Express The link between the PC and the chassis is a x1 cabl...

Страница 18: ...of PCI Express to PCI Express bridge devices On the NI PCIe 8360 the upstream port of the switch is connected to the PCI Express x1 card edge connector and the two downstream ports are connected to th...

Страница 19: ...n MXI Express give status information about power supplies and link state The NI PCIe 8360 has two tri color LEDs one for each port on the panel The NI PXI 8360 has two LEDs one for power supply statu...

Страница 20: ...ress Cable Options MXI Express is available with cables of various lengths Table 3 1 shows the cables available from National Instruments Table 3 1 National Instruments MXI Express Cables Cable Length...

Страница 21: ...NI PCIe 8360 10 7 17 5 cm 4 4 6 9 in Maximum cable length 7 m Slot requirements NI PXI 8360 One system slot NI PCIe 8360 One slot PCI Express Compatibility Fully compatible with the PXI Hardware Speci...

Страница 22: ...ordance with IEC 60068 2 1 and IEC 60068 2 2 Operating relative humidity 10 to 90 noncondensing tested in accordance with IEC 60068 2 56 Storage Environment Ambient temperature range 20 to 70 C tested...

Страница 23: ...60068 2 64 Nonoperating test profile exceeds the requirements of MIL PRF 28800F Class 3 NI PCIe 8360 Maximum altitude 2 000 m Pollution Degree 2 Indoor use only Operating Environment Ambient temperat...

Страница 24: ...ct is designed to meet the requirements of the following standards of safety for electrical equipment for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CAN CSA C22 2 No 6101...

Страница 25: ...ional regulatory compliance information To obtain the DoC for this product visit ni com certification search by model number or product line and click the appropriate link in the Certification column...

Страница 26: ...up to 255 bus segments MXI Express does not limit this number but the maximum number of bus segments allowed can be BIOS or operating system dependent Also a computer may already have several PCI bus...

Страница 27: ...the operating system will provide a mechanism for you to ignore the MXI Express configuration device that is built into the MXI Express hardware MXI 3 required optimization software Does MXI Express r...

Страница 28: ...multichassis PXI system Yes Different MXI kits can be intermixed to connect multiple PXI chassis together As mentioned previously an individual MXI 3 or MXI 4 board will not cable directly to a MXI E...

Страница 29: ...l Instruments Application Engineers make sure every question receives an answer For information about other technical support options in your area visit ni com services or contact your local office at...

Страница 30: ...i com calibration If you searched ni com and could not find the answers you need contact your local office or NI corporate headquarters Phone numbers for our worldwide offices are listed at the front...

Страница 31: ...dividual circuitry in a computer Typically a bus is the expansion vehicle to which I O or other devices are connected Examples of PC buses are the AT bus NuBus Micro Channel and EISA bus bus master a...

Страница 32: ...s manufactured I IEEE Institute of Electrical and Electronics Engineers P PCI Peripheral Component Interconnect a high performance expansion bus architecture originally developed by Intel to replace I...

Страница 33: ...Glossary National Instruments Corporation G 3 MXI Express Series User Manual X x1 a link or port with one physical lane...

Страница 34: ...itional star figure 1 2 configuration basic figure 1 2 conventions used in the manual vii D Declaration of Conformity NI resources C 1 diagnostic tools NI resources C 1 documentation conventions used...

Страница 35: ...3 1 functional unit descriptions 3 2 hardware 3 1 P PCI Express x1 card edge connector 3 2 switch 3 2 PCI Express to PCI bridge 3 3 physical specifications A 1 programming examples NI resources C 1 R...

Страница 36: ...Index National Instruments Corporation I 3 MXI Express Series User Manual U unpacking 1 3 W Web resources C 1...

Отзывы: