![background image](http://html1.mh-extra.com/html/national-instruments/ni-9482/ni-9482_user-manual-and-specifications_3440227014.webp)
NI 9482
|
© National Instruments
|
13
Output Characteristics
Number of channels.......................... 4 electromechanical relay
channels
Relay type ......................................... Single pole single throw
(SPST)
Power-on output state ....................... Channels off
Switching capacity (resistive load)
Switching voltage....................... 60 VDC max, 250 V
rms
max
Switching current, per channel
One channel on .................... 2.5 A max at 30 VDC,
1 A max at 60 VDC,
2.5 A max at 250 V
rms
Two channels on .................. 2 A max at 30 VDC,
1 A max at 60 VDC,
2 A max at 250 V
rms
All channels on .................... 1.5 A max at 30 VDC,
1 A max at 60 VDC,
1.5 A max at 250 V
rms
Resistance per channel,
channel on......................................... 0.2
Ω