background image

This document explains how to connect to the NI 9475.

Note

 

Before you begin, complete the software and

hardware installation procedures in your chassis
documentation.

Note

 

The guidelines in this document are specific to

the NI 9475. The other components in the system might
not meet the same safety ratings. Refer to the
documentation for each component in the system to
determine the safety and EMC ratings for the entire
system.

Safety Guidelines

Operate the NI 9475 only as described in this document.

Caution

 

Do not operate the NI 9475 in a manner not

specified in this document. Product misuse can result in
a hazard. You can compromise the safety protection
built into the product if the product is damaged in any
way. If the product is damaged, return it to NI for
repair.

2

  | 

ni.com

  | 

NI 9475 Getting Started Guide

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Содержание NI 9475

Страница 1: ...derutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In s...

Страница 2: ...GETTING STARTED GUIDE NI 9475 8 Channel 60 V High Speed Sourcing Digital Output Module hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www...

Страница 3: ...h component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9475 only as described in this document Caution Do not operate the NI 9475 in a...

Страница 4: ...cuits not directly connected to the electrical distribution system referred to as MAINS voltage MAINS is a hazardous live electrical supply system that powers equipment This category is for measuremen...

Страница 5: ...is performed only by qualified personnel adhering to local electrical standards Caution Do not mix hazardous voltage circuits and human accessible circuits on the same module Caution Ensure that devic...

Страница 6: ...jury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Caution Do not remove modules unless power has been swit...

Страница 7: ...X certified Each NI 9475 is marked II 3G and is suitable for use in Zone 2 hazardous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9475 in Gas Group IIC hazardous locations...

Страница 8: ...ents and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in indu...

Страница 9: ...y Lloyd s Register certification for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requir...

Страница 10: ...idity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 2 000 m Indoor use only Note Refer to the device datasheet on ni com manuals for complete specifications Connectin...

Страница 11: ...DO6 Vsup DO7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 0 3 4 7 Signals Each channel of the NI 9475 has a DO pin to which you can connect a device Each channel also has a COM pi...

Страница 12: ...ect an external power supply to the NI 9475 This power supply provides the current for the devices you connect to the module Connect the positive lead of the power supply to Vsup and the negative lead...

Страница 13: ...ations of the module Connect the device to DO and connect the common of the device to COM Figure 2 Connecting a Device to the NI 9475 External Power Supply Device COM DO Vsup NI 9475 Note When the dev...

Страница 14: ...connect any number of channels together in parallel For example if you want to drive 4 A of current connect DO 0 3 in parallel as shown in the following figure You must turn all parallel channels on...

Страница 15: ...nal Power Supply Device Vsup I O Protection The NI 9475 provides overcurrent protection Each channel has circuitry that protects it from current surges resulting from short circuits as described in th...

Страница 16: ...depends on factors such as the current level temperature and power supply Higher inrush currents that exist for less than the trip time The circuit protection does not trip Note Refer to the NI 9475...

Страница 17: ...if an overcurrent condition occurs A channel LED may be on even if the channel is off because of an overcurrent condition To determine if the channel is in an overcurrent state measure the voltage be...

Страница 18: ...the cause of an overcurrent condition reset the channel by turning it off Alternatively you can disconnect the external power supply from the module However doing so disconnects power from all the mod...

Страница 19: ...ATED INFORMATION Services ni com services NI 9475 Datasheet NI RIO Help LabVIEW FPGA Help NI 9475 Datasheet NI DAQmx Help LabVIEW Help C Series Documentation Resources ni com info cseriesdoc 18 ni com...

Страница 20: ...istration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European C...

Страница 21: ...chnology refer to the appropriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about e...

Страница 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: