for measurements of voltages from specially protected secondary circuits. Such
voltage measurements include signal levels, special equipment, limited-energy
parts of equipment, circuits powered by regulated low-voltage sources, and
electronics.
Caution
Do not connect the NI 9146 to signals or use for measurements
within Measurement Categories II, III, or IV.
Note
Measurement Categories CAT I and CAT O are equivalent. These test
and measurement circuits are not intended for direct connection to the
MAINS building installations of Measurement Categories CAT II, CAT III, or
CAT IV.
Safety and Hazardous Locations Standards
This product is designed to meet the requirements of the following electrical
equipment safety standards for measurement, control, and laboratory use:
■
IEC 61010-1, EN 61010-1
■
UL 61010-1, CSA 61010-1
■
EN 60079-0:2012, EN 60079-15:2010
■
IEC 60079-0: Ed 6, IEC 60079-15; Ed 4
■
UL 60079-0; Ed 5, UL 60079-15; Ed 3
■
CSA 60079-0:2011, CSA 60079-15:2012
Note
For UL and other safety certifications, refer to the product label or
the
section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for sensitive
electrical equipment for measurement, control, and laboratory use:
■
EN 61326-2-1 (IEC 61326-2-1): Class A emissions; Industrial immunity
■
EN 55011 (CISPR 11): Group 1, Class A emissions
ni.com
24
NI-9146 Safety, Environmental, and Regulatory Information