Operating shock (IEC 60068-2-27) 30 g, 11 ms half sine; 50 g, 3 ms half sine;
18 shocks at 6 orientations
Operating vibration
Random (IEC 60068-2-64)
5 g
rms
, 10 Hz to 500 Hz
Sinusoidal (IEC 60068-2-6)
5 g, 10 Hz to 500 Hz
Cabling
The following table shows the standard Ethernet cable wiring connections for both
normal and crossover cables.
Pin Connector 1
Connector 2 (Normal)
Connector 2 (Crossover)
1
white/orange
white/orange
white/green
2
orange
orange
green
3
white/green
white/green
white/orange
4
blue
blue
blue
5
white/blue
white/blue
white/blue
6
green
green
orange
7
white/brown
white/brown
white/brown
8
brown
brown
brown
Table 5. Ethernet Cable Wiring Connections
Figure 15. Ethernet Connector Pinout
Connector 1
Connector 2
Pin 1
Pin 1
Pin 8
Pin 8
© National Instruments
27
NI-9146 Safety, Environmental, and Regulatory Information