National Instruments Module SCXI-1125 Скачать руководство пользователя страница 18

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on NI trademarks. Other product and company names mentioned herein 

are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: 

Help»Patents

 in your software, 

the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements 

(EULAs) and third-party legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES 
AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in 
this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, 
and DFAR 252.227-7015.

© 2000–2015 National Instruments. All rights reserved.

370271B-01

Oct15

World Wide Support and Services

The National Instruments website is your complete resource for technical 
support. At 

ni.com/support

 you have access to everything from 

troubleshooting and application development self-help resources to email 
and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, 

extended warranty, and other services.

Visit 

ni.com/register

 to register your National Instruments product. 

Product registration facilitates technical support and ensures that you 
receive important information updates from NI.

National Instruments corporate headquarters is located at 11500 North 
Mopac Expressway, Austin, Texas, 78759-3504. National Instruments also 
has offices located around the world. For telephone support in the United 
States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United 
States, visit the Worldwide Offices section of 

ni.com/niglobal

 to access 

the branch office websites, which provide up-to-date contact information, 
support phone numbers, email addresses, and current events.

Содержание Module SCXI-1125

Страница 1: ...rocedure 5 Adjustment Procedure 10 Verifying Adjusted Values 12 Test Limits 13 Gain and Offset 13 SCXI 1125 Front and Rear Panel Diagrams 15 World Wide Support and Services 18 Conventions The followin...

Страница 2: ...are The SCXI 1125 calibration procedure requires the NI DAQmx driver NI recommends using the latest driver that supports both your development environment and the SCXI 1125 NI DAQmx includes high leve...

Страница 3: ...itions Follow these guidelines to optimize the connections and the environment during calibration Keep connections to the SCXI 1125 as short as possible Long cables and wires can act as antennas picki...

Страница 4: ...ment Procedure Perform an external calibration that adjusts the SCXI 1125 calibration constants with respect to a known voltage source 4 Verifying Adjusted Values Perform another verification to ensur...

Страница 5: ...u configure a device in MAX the device is assigned a device identifier In this calibration document the functions used for demonstrating the calibration process use the device identifiers Dev1 for the...

Страница 6: ...set calibration constants for each gain setting per analog input channel A complete verification of the inputs involves measuring the accuracy at all possible gain settings on all channels of the SCXI...

Страница 7: ...annels Refer to the SCXI 1320 High Voltage Terminal Block Installation Guide and Specifications for connection instructions If you are not using the recommended SCXI 1320 refer to Table 4 for the fron...

Страница 8: ...ed Gain LabVIEW Block Diagram NI DAQmx Function Call Call DAQmxCreateAIVoltageChan with the following parameters taskHandle taskHandle physicalChannel SC1Mod1 aiX nameToAssignToChannel myVoltageChanne...

Страница 9: ...VIEW Block Diagram NI DAQmx Function Call Call DAQmxCfgSampClkTiming with the following parameters taskHandle taskHandle source rate 1000 0 activeEdge DAQmx_Val_Rising sampleMode DAQmx_Val_FiniteSamps...

Страница 10: ...points in Table 2 You have finished verifying the analog input accuracy of the SCXI 1125 Adjustment Procedure The adjustment procedure adjusts the gain and offset calibration constants on the SCXI 112...

Страница 11: ...ents of the SCXI 1125 If the calibration signal source is floating connect AI to the SCXI chassis ground using the ground lug available on the SCXI terminal block 3 Start an external calibration sessi...

Страница 12: ...is step 10 Repeat steps 3 through 9 for all gain values in Table 3 11 Repeat steps 2 through 10 for the remaining channels You have finished adjusting the gain and offset of the SCXI 1125 Verifying Ad...

Страница 13: ...n Table 2 do not include DAQ device errors Table 2 Upper and Lower Limit Channel Settings Gain Range Test Point Upper Limit V Lower Limit V 1 5 4 950000 4 982047 4 917953 1 0 0 000000 0 006802 0 00680...

Страница 14: ...89 0 009811 500 0 0 000000 0 000038 0 000038 500 0 01 0 009900 0 009811 0 009989 1000 0 005 0 00495 0 005007 0 004893 1000 0 0 000000 0 000031 0 000031 1000 0 005 0 004950 0 004893 0 005007 2000 0 002...

Страница 15: ...nts Gain Set Points V 1 4 5 3 1 5 0 1 5 3 4 5 2 2 25 1 5 0 75 0 0 75 1 5 2 25 5 0 9 0 6 0 3 0 0 3 0 6 0 9 10 0 45 0 3 0 15 0 0 15 0 3 0 45 20 0 225 0 15 0 075 0 0 075 0 15 0 225 50 0 09 0 06 0 03 0 0...

Страница 16: ...no connection no pin 32 AI 0 AI 0 31 30 AI 1 AI 1 29 28 NC NC 27 26 AI 2 AI 2 25 24 AI 3 AI 3 23 22 NC NC 21 20 AI 4 AI 4 19 18 AI 5 AI 5 17 16 NC NC 15 14 AI 6 AI 6 13 12 AI 7 AI 7 11 10 NC NC 9 8 R...

Страница 17: ...2 7 8 AO 2 AO 3 9 10 AO 3 AO 4 11 12 AO 4 AO 5 13 14 AO 5 AO 6 15 16 AO 6 AO 7 17 18 AO 7 OUT REF 19 20 21 22 23 24 D GND SER DAT IN 25 26 SER DAT OUT DAQ D A 27 28 SLOT 0 SEL 29 30 31 32 D GND 33 34...

Страница 18: ...et forth in FAR 52 227 14 DFAR 252 227 7014 and DFAR 252 227 7015 2000 2015 National Instruments All rights reserved 370271B 01 Oct15 World Wide Support and Services The National Instruments website i...

Отзывы: