If you plan to use a regulated power supply, you may encounter a problem with regeneration.
If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is
transferred back to the power supply. This can trip the overvoltage protection of a switching
power supply, causing it to shut down. Unregulated power supplies are better suited for
applications with significant regeneration as they generally do not have overvoltage protection
and have large capacitors for storing energy coming back from the drive. Refer to
for more information.
Connecting the Device Using Ethernet
This process requires three steps:
1. Physically connect the device to your network (or directly to the PC).
2. Set the drive IP address.
3. Set the appropriate networking properties on your PC.