NI ISM-7413 Ethernet Integrated Stepper User Manual
Operating temperature range ............................0 °C to 85 °C
Ambient temperature range ..............................0 °C to 40 °C
Accessories
Regeneration clamp ..........................................NI SMD-7700, NI part number 748908-01
Power Supply
NI PS-12 ...................................................24 VDC, 6.3 A, NI part number 748906-01
NI PS-13 ...................................................48 VDC, 6.7A, NI part number 748907-01
Alarm Codes
The LED lights indicate any errors with the following blink codes:
Table 2.
Status LED Blink Code Definitions
Blink sequence
Code
Error
G
Solid green
No alarm, motor disabled
GG (slow)
Flashing green slowly
No alarm, motor enabled
GG (rapid)
Flashing green quickly
Q Program running
RG
1 red, 1 green
Motor stall (encoder-equipped only)
RGG
1 red, 2 green
Move attempted, drive disabled
RRG
2 red, 1 green
CCW limit
RRGG
2 red, 2 green
CW limit
RRRG
3 red, 1 green
Drive overheating
RRRGG
3 red, 2 green
Internal voltage out of range
RRRGGG
3 red, 3 green
Blank Q segment
RRRRG
4 red, 1 green
Power supply overvoltage
RRRRGG
4 red, 2 green
Power supply undervoltage
RRRRGGG
4 red, 3green
Flash memory backup error
RRRRRG
5 red, 1 green
Over current / short circuit
RRRRRGG
5 red, 2 green
I/O occupied
RRRRRRG
6 red, 1 green
Open motor winding
RRRRRRGG
6 red, 2 green
Bad encoder signal
Содержание ISM-7413