© National Instruments
|
6-3
NI 17xx Smart Camera User Manual
IMG ACQ LED
The IMG ACQ LED briefly lights green when an image is captured and ready for analysis. Fast
frame rates can give this LED the appearance of being continuously lit.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that the NI Smart Camera
has shut down because the maximum internal temperature was exceeded. Refer to the
section of Chapter 8,
Thermal Considerations and Mounting
, for information
about measuring the temperature of the smart camera. Refer to Appendix A,
, for
complete specifications.
PASS LED
The PASS LED is a green LED that is user-configurable through the IMAQ property node in
LabVIEW or the
Read/Write I/O
step in Vision Builder AI.
3 Flashes
Green
The smart camera is in safe mode because the SAFE MODE
DIP switch is in the ON position. Refer to the
section for information about the SAFE MODE DIP
switch.
4 Flashes
Green
The smart camera has experienced two consecutive software
exceptions. The smart camera automatically restarts after an
exception. After the second exception, the smart camera
remains in the exception state, alerting you to resolve the
problem. Reinstall software on the smart camera or contact
National Instruments for assistance. Refer to
Getting Started
with the NI 17xx Smart Camera
for information about
installing software on the smart camera.
5 Flashes
Green
The smart camera detects a critical error. Reinstall software on
the smart camera or contact National Instruments for
assistance. Refer to
Getting Started with the NI 17xx Smart
Camera
for information about installing software on the smart
camera.
Flashing
Red
The smart camera detects a software crash or hang.
Contact National Instruments for assistance.
Solid
Red
The smart camera detects a critical firmware error. Contact
National Instruments for assistance.
Table 6-1.
STATUS LED Indications (Continued)
LED
Behavior
LED
Color
Indication
Содержание ISC-1762
Страница 1: ...ISC 1762...