6-4
|
ni.com
Chapter 6
LEDs and DIP Switches
FAIL LED
The FAIL LED is a red LED that is user-configurable through the IMAQ property node in
LabVIEW or the
Read/Write I/O
step in Vision Builder AI.
If the IMG ACQ LED and the FAIL LED both flash red, it indicates that the NI Smart Camera
has shut down because the maximum internal temperature was exceeded. Refer to the
Thermal Considerations and Mounting
, for information
about measuring the temperature of the smart camera. Refer to Appendix A,
complete temperature specifications.
Configuring DIP Switches
This section describes the SAFE MODE, IP RESET, NO APP, and CONSOLE DIP switches on
the NI Smart Camera. To turn on a DIP switch, lift the DIP switch cover and move the switch to
the ON position.
Caution
To avoid potential damage to your device, use care when configuring DIP
switches. Do not use blunt tools or excessive force when changing the switch
position.
SAFE MODE Switch
To start the NI Smart Camera in safe mode, move the SAFE MODE switch to the ON position
and reapply power or restart the smart camera. If the switch is in the ON position when the smart
camera starts, the smart camera launches only the essential services required for updating
configuration information and installing software. The LabVIEW Real-Time engine does not
launch. Use safe mode to reconfigure the smart camera TCP/IP settings, update firmware, and
to install or update the software on the smart camera.
If the software on the smart camera is corrupted, start the smart camera in safe mode and update
the software. To resume normal operations, move the SAFE MODE
switch to the OFF
position
and reapply power or restart the smart camera. Refer to
Getting Started with the NI 17xx Smart
Camera
for information about updating the software on the smart camera.
The STATUS LED flashes green three times when the smart camera is in safe mode. Keep the
SAFE MODE switch in the OFF position during normal operation.