f)

Click 

Next

.

g)

Select any additional add-ons you would like to install to the IC-3121.

h)

Click 

Next

. Review the list of software to install.

i)

Click 

Next

 to begin downloading the software to the IC-3121. When MAX finishes

downloading the software, the IC-3121 restarts.

j)

Click 

Finish

.

7.

Install custom software. You do not need to install custom software if you installed a
recommended software set.
a)

Expand the IC-3121 under 

Remote Systems

.

b)

Click the 

Software

 item below the IC-3121 in the configuration tree.

c)

Click 

Add/Remove Software

 on the NI MAX toolbar to launch the LabVIEW Real-

Time Software Wizard.

d)

Enter 

admin

 as the username and leave the password field blank.

e)

If you are given a choice of recommended software sets, choose 

Custom software

installation

 and click 

Next

 to proceed with a custom installation.

f)

Select the NI Industrial Controller Device Drivers, and any additional software you
would like to install on the IC-3121.

g)

Click 

Next

. Review the list of software to install.

h)

Click 

Next

 to begin downloading the software to the IC-3121. When NI MAX

finishes downloading the software, the IC-3121 restarts.

i)

Click

 Finish

.

8.

Connect hardware to the IC-3121. The NI Industrial Controller Device Drivers enable the
IC-3121 to detect any hardware connected.

9.

Select the target in the configuration tree and click the 

Refresh

 button. Refresh the target

whenever you connect new hardware.

10. Expand 

Devices and Interfaces

 under the IC-3121 in the configuration tree. Select the

hardware connected to the IC-3121 from the list. You can view or modify the device
settings as allowed by the hardware.

Setting a System Password

Complete the following steps to set a system password.

Note

 

The default username for the IC-3121 is 

admin

. There is no default

password for the IC-3121, so you must leave the password field blank when logging
in until you set a system password.

1.

In MAX, right-click the IC-3121 and select 

Web Configuration

.

The NI Web-Based Configuration and Monitoring utility opens in the default browser and
is where you set the password. If you have not installed Microsoft Silverlight,
NI Web-based Configuration and Monitoring prompts you to do so.

2.

Enter a unique name for your system in the 

Hostname

 field.

3.

Click the 

Security Configuration

 icon.

4.

Click 

Login

.

5.

In the 

Login

 dialog box, enter the username 

admin

 and leave the password field blank.

8

  | 

ni.com

  | 

IC-3121 Getting Started Guide

Содержание IC-3121

Страница 1: ...shooting 9 Where to Go Next 13 Worldwide Support and Services 13 Safety Information Caution The following paragraphs contain important safety information you must follow when installing and operating...

Страница 2: ...efore returning it to service You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines...

Страница 3: ...ibility of static electricity damage Refer to the following figures while configuring the hardware Figure 1 IC 3121 Power Connectors and Reset Button SYSTEM 12 24 V C V ISO 5 24 V 2 3 1 4 C ISO V ISO...

Страница 4: ...3 0 Ports 6 44 pin Digital I O Connector Connecting the System Power Supply NI recommends the following power supply for the IC 3121 Power Supply Part Number NI PS 15 Industrial Power Supply 781093 01...

Страница 5: ...lug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 5 Install the power connector plug into the SYSTEM power receptacle on the IC 3121 chassis and tighten the connector sc...

Страница 6: ...ws to 0 4 N m 3 5 lb in of torque 6 Turn on the external power source Configuring the IC 3121 for NI Linux Real Time The real time version of the IC 3121 ships preloaded with NI Linux Real Time Comple...

Страница 7: ...NI MAX to set a system password on the target Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install the drivers onto the device Complete the following steps to instal...

Страница 8: ...the IC 3121 restarts i Click Finish 8 Connect hardware to the IC 3121 The NI Industrial Controller Device Drivers enable the IC 3121 to detect any hardware connected 9 Select the target in the configu...

Страница 9: ...P connection it connects to the network with a link local IP address 169 254 x x Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install other National Instruments soft...

Страница 10: ...rform an IP RESET The cable you are using may be inappropriate for the speed of your network causing network communication dropout While 1 000 Mbps communication over short cable lengths can be achiev...

Страница 11: ...ivers on page 7 Cannot Drive Isolated Outputs Verify that you have power connected to the VISO and CISO inputs on the IC 3121 isolated power connector and that the contact at the screw terminals is so...

Страница 12: ...the exception state alerting you to resolve the problem Reinstall software on the IC 3121 or contact NI for assistance Refer to the IC 3121 Getting Started Guide for information about installing soft...

Страница 13: ...Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you rec...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: