If the BIOS setting Restore After Power Loss is set to 

Stay Off

, the IC-3121 may be powered,

but turned off. Use the power button to turn on the device.

Where to Go Next

The following documents and resources contain information you may find helpful as you use
the IC-3121 in an application. Refer to the National Instruments Product Manuals Library at 

ni.com/manuals

 for the most recent versions of product documentation.

IC-3121 Specifications

—Contains detailed specifications for the IC-3121.

IC-3121 User Manual

—Contains connector pinouts, configuration information, mounting

information, and answers to common troubleshooting questions.

NI CVS I/O Accessory User Manual

—Contains installation and operation instructions for

the NI CVS I/O Accessory.

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

, you have

access to everything from troubleshooting and application development self-help resources to
email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your NI product. Product registration facilitates technical

support and ensures that you receive important information updates from NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas,
78759-3504. NI also has offices located around the world. For telephone support in the United
States, create your service request at 

ni.com/support

 or dial 1 866 ASK MYNI (275 6964). For

telephone support outside the United States, visit the 

Worldwide Offices

 section of 

ni.com/

niglobal

 to access the branch office websites, which provide up-to-date contact information,

support phone numbers, email addresses, and current events.

IC-3121 Getting Started Guide

  | 

© National Instruments

  | 

13

Содержание IC-3121

Страница 1: ...shooting 9 Where to Go Next 13 Worldwide Support and Services 13 Safety Information Caution The following paragraphs contain important safety information you must follow when installing and operating...

Страница 2: ...efore returning it to service You must insulate signal connections for the maximum voltage for which the device is rated Do not exceed the maximum ratings for the device Remove power from signal lines...

Страница 3: ...ibility of static electricity damage Refer to the following figures while configuring the hardware Figure 1 IC 3121 Power Connectors and Reset Button SYSTEM 12 24 V C V ISO 5 24 V 2 3 1 4 C ISO V ISO...

Страница 4: ...3 0 Ports 6 44 pin Digital I O Connector Connecting the System Power Supply NI recommends the following power supply for the IC 3121 Power Supply Part Number NI PS 15 Industrial Power Supply 781093 01...

Страница 5: ...lug and tighten the terminal screw to 0 2 to 0 25 N m 1 8 to 2 2 lb in of torque 5 Install the power connector plug into the SYSTEM power receptacle on the IC 3121 chassis and tighten the connector sc...

Страница 6: ...ws to 0 4 N m 3 5 lb in of torque 6 Turn on the external power source Configuring the IC 3121 for NI Linux Real Time The real time version of the IC 3121 ships preloaded with NI Linux Real Time Comple...

Страница 7: ...NI MAX to set a system password on the target Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install the drivers onto the device Complete the following steps to instal...

Страница 8: ...the IC 3121 restarts i Click Finish 8 Connect hardware to the IC 3121 The NI Industrial Controller Device Drivers enable the IC 3121 to detect any hardware connected 9 Select the target in the configu...

Страница 9: ...P connection it connects to the network with a link local IP address 169 254 x x Installing the NI Industrial Controller Device Drivers Before using the IC 3121 install other National Instruments soft...

Страница 10: ...rform an IP RESET The cable you are using may be inappropriate for the speed of your network causing network communication dropout While 1 000 Mbps communication over short cable lengths can be achiev...

Страница 11: ...ivers on page 7 Cannot Drive Isolated Outputs Verify that you have power connected to the VISO and CISO inputs on the IC 3121 isolated power connector and that the contact at the screw terminals is so...

Страница 12: ...the exception state alerting you to resolve the problem Reinstall software on the IC 3121 or contact NI for assistance Refer to the IC 3121 Getting Started Guide for information about installing soft...

Страница 13: ...Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilitates technical support and ensures that you rec...

Страница 14: ...party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain rel...

Отзывы: