Appendix A
Multiline Interface Messages
© National Instruments Corp.
A-5
GPIB-232CT User Manual
Interface Message Reference List (continued)
Mnemonic Message
Interface
Function(s)
REMOTE MESSAGES RECEIVED (continued)
PPC
parallel poll configure
PP
[PPD]
parallel poll disable
PP
[PPE]
parallel poll enable
PP
PPRn
parallel poll response n
(via C)
PPU
parallel poll unconfigure
PP
REN remote
enable
RL
RFD
ready for data
SH
RQS
request service
(via L, LE)
[SDC]
selected device clear
DC
SPD
serial poll disable
T, TE
SPE
serial poll enable
T, TE
SRQ
service request
(via C)
STB
status byte
(via L, LE)
TCT or [TCT]
take control
C
UNL unlisten
L,
LE
REMOTE MESSAGES SENT
ATN attention
C
DAB data
byte
DAC data
accepted
AH
DAV data
valid
SH
DCL
device clear
(via C)
END end
(via
T)
GET
group execute trigger
(via C)
GTL
go to local
(via C)
IDY identify
C
IFC interface
clear C
LLO
local lockout
(via C)
MLA or [MLA]
my listen address
(via C)
MSA or [MSA]
my secondary address
(via C)
MTA or [MTA]
my talk address
(via C)
OSA
other secondary address
(via C)
OTA
other talk address
(via C)
PCG
primary command group
(via C)
PPC
parallel poll configure
(via C)
[PPD]
parallel poll disable
(via C)
[PPE]
parallel poll enable
(via C)
PPRn
parallel poll response n
PP
PPU
parallel poll unconfigure
(via C)
REN remote
enable
C
RFD
ready for data
AH