Caution
To ensure the specified EMC performance, you must use an isolated cable
with the RS-485 serial port, such as NI part number 184428-01.
Caution
To ensure the specified EMC performance, the length of any cable
connected to the video, USB host ports, and V2 ports must be no longer than 3 m
(10 ft). The length of any cable connected to the RS-232 and RS-485 ports must be
no longer than 30 m (100 ft).
Caution
The USB device port is intended only for use in device configuration,
application deployment, debug, and maintenance.
Caution
To ensure the specified EMC performance, product installation requires
either special considerations or user-installed, add-on devices. Refer to the following
sections for more information.
Related Information
Connecting the cRIO-9039 to Ground
on page 7
Connecting the cRIO-9039 to Power
on page 8
Special Conditions for Marine Applications
Some products are Lloyd’s Register (LR) Type Approved for marine (shipboard) applications.
To verify Lloyd’s Register certification for a product, visit
ni.com/certification
and search for
the LR certificate, or look for the Lloyd’s Register mark on the product.
Caution
In order to meet the EMC requirements for marine applications, install the
product in a shielded enclosure with shielded and/or filtered power and input/output
ports. In addition, take precautions when designing, selecting, and installing
measurement probes and cables to ensure that the desired EMC performance is
attained.
Preparing the Environment
Ensure that the environment in which you are using the cRIO-9039 meets the following
specifications.
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2)
-20 °C to 55 °C
Operating humidity (IEC 60068-2-56)
10% RH to 90% RH, noncondensing
Pollution degree
2
Maximum altitude
5,000 m
Indoor use only.
Note
Refer to the device specifications on
ni.com/manuals
for complete
specifications.