Barrel length

9.52 mm (0.375 in.)

Center positive

Caution

 

Clean the CPS-8910 with a soft nonmetallic brush. Make sure that the

device is completely dry and free from contaminants before returning it to service.

Environmental

Operating environment

Operating temperature

0 °C to 55 °C
(32 °F to 140 °F)

Operating humidity

10% to 90% RH, noncondensing

Storage environment

Storage temperature

-40 °C to 85 °C
(-40 °F to 185 °F)

Storage humidity

5% to 95% RH, noncondensing

Maximum altitude

2,000 m (800 mbar)

Pollution Degree

2

Indoor use only.

Safety

This product is designed to meet the requirements of the following electrical equipment safety
standards for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1

Note

 

For UL and other safety certifications, refer to the product label or the 

Online

Product Certification

 section.

Electromagnetic Compatibility

This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:

EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity

EN 55011 (CISPR 11): Group 1, Class A emissions

EN 55022 (CISPR 22): Class A emissions

EN 55024 (CISPR 24): Immunity

AS/NZS CISPR 11: Group 1, Class A emissions

AS/NZS CISPR 22: Class A emissions

6

  | 

ni.com

  | 

CPS-8910 Getting Started Guide

Содержание CPS-8910

Страница 1: ...mental 6 Safety 6 Electromagnetic Compatibility 6 CE Compliance 7 Online Product Certification 7 Environmental Management 7 Waste Electrical and Electronic Equipment WEEE 7 RoHS 8 Worldwide Support an...

Страница 2: ...llowing LEDs Power indicator illuminates when the CPS 8910 is powered on Up Stream Off no connection On connected to a x8 upstream device Blinking connected to a x4 upstream device Ports 1 through 8 O...

Страница 3: ...ulatory requirements and limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonable protection against harmful interference when...

Страница 4: ...8910 and connect devices to it Caution When mounting the equipment in the rack do not create a hazardous condition due to uneven mechanical loading 1 Mount the CPS 8910 in the desired position by ins...

Страница 5: ...ports One Gen 2 x8 and one Gen 1 x4 PCI Express upstream connectors with mutual lockout mechanism Downstream ports Eight Gen 1 PCI Express x4 downstream cable connectors LED indicators Single power in...

Страница 6: ...designed to meet the requirements of the following electrical equipment safety standards for measurement control and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 Note For UL and other...

Страница 7: ...aration of Conformity DoC for additional regulatory compliance information To obtain product certifications and the DoC for this product visit ni com certification search by model number or product li...

Страница 8: ...support in the United States create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni co...

Отзывы: