8274/9274 PROCEDURE
Page 23
POWER SOURCE VOLTAGE -
FOR 115 VOLTAGE
Jobsite receptacles can vary. Check voltage at receptacles on the
jobsite for the best voltage supply. 15 amp GFI outlets are not
recommended.
NOTE: K
ITCHEN
,
BATHROOM
,
OUTDOOR AND GARAGE RECEPTACLES MAY BE
GFI. GFI
RECEPTACLES CAN BE
“
SENSITIVE
”. S
OME
GFI
RECEPTACLES WILL
NOT ALLOW THE MACHINE TO RUN
. T
O TEST OUTLET
,
GO TO SWITCH BOX AND
CHECK CIRCUITS
. T
URN OFF TO TEST
.
A #5110-501 Voltage Meter (Figure A) easily plugs into any outlet to
determine the amount of voltage at that specific outlet.
The use of a #5110-500 Buck and Boost Transformer (Figure B)
improves voltage out of a receptacle.
Figure A
Figure B
POWER CORD
Use a 12 gauge power cord not exceeding 50 feet in length. If there is loss of power, convert to a 10
gauge power cord.
Do not allow the rotating plates to come into contact with the supply cord.
Regularly examine the supply cord for damage, such as cracking or aging. If damage is found, replace
the cord before further use.
Only replace the supply cord with the type specified in this instruction manual.