5280 PROCEDURES
HYDRAULIC FLUID LEVEL
• Machine is run at a low temperature and pressure.
• Check fluid level if there has been a leak, damaged or ruptured hose or a loose fitting.
• Fluid level should be 1'' from the top of the tank (See Figure B).
ADDING OR CHANGING HYDRAULIC FLUID
• Occasionally blow out the Filler Port Cap filter to remove debris.
• Change or add fluid only when needed.
• To add fluid, unscrew Filler Port Cap from top of machine (See Figure A).
• To change fluid, remove Filler Port Cap. Remove drain plug from side of machine (See Figure B). A
container approximately two gallons in size will be needed to drain fluid into (fluid will not be removed
from hoses).
• Machine has a straining system, but add fluid through a filter or funnel with a screen to keep fluid clean.
• Use texaco Rando 46 Hydraulic Oil Light, stock #6280-1 or comparable.
TANK REMOVAL
Removing the tank will be necessary to repair the pump or to replace or service internal hoses.
• Drain tank by removing top Filler Port Cap and Drain Plug on side of machine (See Figure B). A
container approximately two gallons in size will be needed to drain fluid into.
• Replace Drain Plug and Filler Port Cap.
• Remove two lifting bail eyebolts and the two bolts from the back of the tank.
• Disconnect return line on back of tank, carefully lift tank 3'' to 4'' and disconnect suction line. Tank can
now be removed.
FILLER PORT
CAP
DRAIN
PLUG
Figure A
Figure B
Содержание PANTHER 5280
Страница 38: ...Page 37 5280 MATERIAL SAFETY DATA...
Страница 39: ...Page 38 5280 MATERIAL SAFETY DATA...
Страница 40: ...Page 39 5280 MATERIAL SAFETY DATA...
Страница 41: ...Page 40 5280 MATERIAL SAFETY DATA...
Страница 42: ...Page 41 5280 MATERIAL SAFETY DATA...
Страница 43: ...Page 42 5280 MATERIAL SAFETY DATA...