background image

8

Limited Warranty

Nasco warrants to the purchasers of 

CR

i

S

is

™ 

products that they will be free from 

defects  in  material  and  workmanship  for  a  period  of  three  years  from  the  date 
of  purchase.  Nasco  will  repair  any  defect  reported  within  three  years  of  the  date 
of purchase at no charge. Products found to be defective may be returned to the 
authorized Nasco dealer from whom the item was  purchased, or returned directly 
to Nasco. Nasco will be liable under this limited warranty only if 

CR

i

S

is

™ 

products 

have been serviced properly as directed in the operating manual.

Nasco  will  not  be  responsible  for  damage  caused  by  unauthorized  repairs  or  
modifications that have been made, or if the product has been damaged through 
misuse, accident, or abuse. This warranty does not cover wear and tear or expend-
ables  such  as  batteries,  lubricant,  and  replacement  lungs.  There  are  no  other 
expressed or implied warranties of merchantability, fitness of purpose, or otherwise 
on “Airway Larry”

 

products, parts, and accessories.

Table of Contents 

page

 

Introduction 

Airway Management Trainer 

3

Defibrillation Chest Skin 

7

Once your manikin is connected to your 
patient simulator, you will be able to pick 
up the ECG waves either through the 
monitor hook-ups on the skin or through 
the two disks attached to the skin on the 
defibrillation sites.

These disks will enable you to pick up 
the ECG wave using either the “Quick 
Look” paddle option or directly through 
gel pads, just like on a real patient.

It is possible to use AED gel pads with 
the cable connectors built into the gel — 
the same ones you use on patients. In 
an effort to help you save money, Nasco 
does offer a set of defibrillation pad and 
patient simulator adapters that will corre-
spond to your particular AED unit. These 
defibrillation pad and patient simulator 
adapters can be reused again and again. 
They come as a set. (See“Supplies/ 
Replacement Parts” at right.)

Troubleshooting:
Problem:

ECG wave is not being picked up from 
the manikin.

Solution:

1.  Check your connections on the 
patient simulators, one or more may be 
disconnected.

2.  Check to make sure your patient 
simulator is plugged in and working 
properly.

Problem:

ECG wave is inverted.

Solution:

Recheck the position of the red and 
black lead snaps on the patient simulator.

Note:

  If the defibrillation skin is not 

functioning or wiring comes undone, 
please contact us to repair or replace the 
unit. Failure to do so, or unauthorized 
repair may void the warranty or cause 
further harm or damage to you or your 
equipment.

Supplies/Replacement Parts for 
Defibrillation Chest Skin:

LF03656U

  Physio Control  

 

Defibrillation 

 

Pad and Patient  

 

Simulator  

 

Adapter Package

LF03657U

  Marquette Electronics 

 

Defibrillation Pad and 

 

Patient Simulator Adapter 

 

Package

LF03658U

  SpaceLabs, First Medic,  

 

or Laerdal Defibrillation  

 

Pad and Patient Simulator  

 

Adapter Package

LF03961U

 

Zoll Training Cables with 

 

Adapters

LF03962U

 

Physio Control Training 

 

Cables with Adapters

If you need help selecting the training 
pad adapters that correspond to your 
AED unit, please feel free to call us at 
1-800-558-9595 for assistance.

NP 154-06 LF03960.indd   3

3/26/08   11:05:45 AM

Содержание CRiSis LF03960U

Страница 1: ...Advanced Airway Larry TORSO MANIKIN LF03960U INSTRUCTION MANUAL Products by Nasco kin n ...

Страница 2: ...rranty only if CRiSis products have been serviced properly as directed in the operating manual Nasco will not be responsible for damage caused by unauthorized repairs or modifications that have been made or if the product has been damaged through misuse accident or abuse This warranty does not cover wear and tear or expend ables such as batteries lubricant and replacement lungs There are no other ...

Страница 3: ...years of valu able service Cleaning Normal surface soil can be removed from the trainer with mild soapy water Stubborn stains may be removed with REN Cleaner W09919U Simply apply the REN Cleaner to the soiled area and wipe clean with a soft cloth Note Avoid using cleaner around the mouth area if students will be apply ing direct mouth to mouth resuscitation techniques as the cleaner may be toxic i...

Страница 4: ...ral digital and nasal intubation E T E O A PTL LMA and Combitube insertion can all be practiced as well please see Using the Combitube Suction tech niques and proper cuff inflation can also be performed and evaluated Lubrication Before using the Advanced Airway Management Trainer Torso lubricate both the simulator and supplies being used with the Nasco lubricant provided See figures 1 2 Note Nasco...

Страница 5: ...then lift off the plate Disconnect the lungs from the bronchi by pulling the red caps from the white connectors See figure 6 Now that the head has been disconnect ed from the airway rotate it 180 so that it is facing backwards The large tab on the front of the neck should be aligned with the keyway in the torso Tilt the head upward until it snaps free See figure 7 Disengage the smaller rear tabs f...

Страница 6: ... with the neck slightly elevated to ensure that the solution completely fills all airway passages Once completely filled with the bleach solution allow the head to sit for at least 10 minutes Drain as described earlier and repeat the rinsing process to flush out all of the bleach solution Set the head aside and allow it to dry completely Using the Combitube Thoroughly read and follow the instruc t...

Страница 7: ...plate back over the upper compression plate and lungs 6 Reattach the chest skin by adjusting the Velcro edges Again be care ful not to damage the electronics attached to the chest skin Torso Set Up A Connecting the Airway 1 The manikin s airway has been dis connected to prevent damage dur ing shipping To connect the airway remove the chest skin chest plate compression springs and upper compression...

Страница 8: ...ators This is possible via the stan dard four lead snap cable Figure 1 If your patient simulator has only two out put posts the red and black leads must be connected to the patient simulator You may want to connect the manikin to the simulator that came with your defibrillator If your patient simulator doesn t have the standard snap connec tors it will be necessary to purchase the corresponding ad...

Страница 9: ...m the manikin Solution 1 Check your connections on the patient simulators one or more may be disconnected 2 Check to make sure your patient simulator is plugged in and working properly Problem ECG wave is inverted Solution Recheck the position of the red and black lead snaps on the patient simulator Note If the defibrillation skin is not functioning or wiring comes undone please contact us to repa...

Страница 10: ...anagement Head Only LF03609U Child Airway Management Trainer LF03610U Child Airway Management Trainer Head Only LF03611U Child Defibrillation Chest Skin LF03612U Child IV Arm LF03613U Child Blood Pressure Arm LF03614U Child Intraosseous Infusion Femoral Access Leg Only LF03615U Complete Child CRiSis Update Kit LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor...