2

The Advanced “Airway Larry” Manikin is a 
Complete Resuscitation System consisting 
of modular components which allow you 
to create a manikin to suit your changing 
needs. The components may be pur-
chased as a complete package or sepa-
rately to update your existing manikin. 
Update packages are compatible with all 
versions of both 

CPARLENE

®

 and non-

modular Resusci

®

 Anne™*.

This manual will guide you in setting 
up, using, and maintaining each of the 
available components. Each section also 
includes a list of replacement parts, sup-
plies, and auxiliary equipment.

By reading and following all instructions 
carefully and completely, you can be 
sure your 

              

Advanced “Airway 

Larry” Manikin will provide years of valu-
able service.

Cleaning:

Normal surface soil can be removed 
from the trainer with mild soapy water. 
Stubborn stains may be removed with 
REN Cleaner (W09919U). Simply apply 
the REN Cleaner to the soiled area and 
wipe clean with a soft cloth.
 

Note:

 

Avoid using cleaner around the 

mouth area if students will be apply-
ing direct mouth-to-mouth resuscitation 
techniques, as the cleaner may be toxic if 
ingested. NEVER place the trainer on any 
kind of printed paper or plastic. These 
materials, as well as ballpoint pens, will 
transfer indelible stains. Do not use any 
cosmetics. 

List of Components:

•  Advanced “Airway Larry” 

 

    Torso Manikin

•  Defibrillation Chest Skin
•  8-oz. Pump Spray Lubricant
•  20 cc syringe (2)

*Resusci

®

 Anne™ is a trademark of Laerdal Medical Corporation.

NASCO                Defibrillation 
Chest Skin

About the Simulator…

The 

CR

i

S

is

 System Defibrillation Chest 

Skin has been designed to absorb a 
maximum of 360 joules of energy*. 
Although capable of absorbing 360 
joules, we do recommend that the small-
est energy level possible be used while 
training with the skin.

The 

CR

i

S

is

 System Defibrillation Chest 

Skin will enable you to practice defibril-
lation using manual, semi-automatic, 
and automatic external defibrillators 
(AEDs). When using any one of these in 
training, always follow the recommended 
operating procedures for that particular 
defibrillator.

The “Airway Larry” Manikin comes with 
the Defibrillation Chest Skin in place and 
ready for use. Connect the defibrillation 
chest skin to your arrhythmia or patient 
simulator using the four-lead snap cable.

Connecting Your Arrhythmia or 
Patient Simulator:

Nasco has designed the 

CR

i

S

is

 System 

to be compatible with a variety of patient 
simulators. This is possible via the stan-
dard four-lead snap cable (Figure 1). If 
your patient simulator has only two out-
put posts, the red and black leads must 
be connected to the patient simulator.

You may want to connect the manikin 
to the simulator that came with your 
defibrillator. If your patient simulator 
doesn’t have the standard snap connec-
tors, it will be necessary to purchase the 
corresponding adapters from Nasco. To 
order, please see “Supplies/Replacement 
Parts” on page 8.

Figure 1

7

of 360 joules may cause irreparable 
damage to the chest skin, circuitry, 
and patient simulator being used 
— thus voiding Nasco’s warranty and 
endangering your equipment. Nasco 
assumes no liability for damage or 
injury that may be caused by the use 
and/or misuse of this equipment. All 
normal safety precautions for defibril-
lation training should be followed and 
energy levels should be minimized. 
Nasco did not design nor intend this 
Defibrillation Chest Skin to be used as 
anything other than a training appa-
ratus for defibrillation.

Note:

 360 joules is the maximum 

energy level that Nasco recommends 
administering to the Defibrillation 
Chest Skin. Energy levels in excess 

NP 154-06 LF03960.indd   4

3/26/08   11:05:48 AM

Содержание CRiSis LF03960U

Страница 1: ...Advanced Airway Larry TORSO MANIKIN LF03960U INSTRUCTION MANUAL Products by Nasco kin n ...

Страница 2: ...rranty only if CRiSis products have been serviced properly as directed in the operating manual Nasco will not be responsible for damage caused by unauthorized repairs or modifications that have been made or if the product has been damaged through misuse accident or abuse This warranty does not cover wear and tear or expend ables such as batteries lubricant and replacement lungs There are no other ...

Страница 3: ...years of valu able service Cleaning Normal surface soil can be removed from the trainer with mild soapy water Stubborn stains may be removed with REN Cleaner W09919U Simply apply the REN Cleaner to the soiled area and wipe clean with a soft cloth Note Avoid using cleaner around the mouth area if students will be apply ing direct mouth to mouth resuscitation techniques as the cleaner may be toxic i...

Страница 4: ...ral digital and nasal intubation E T E O A PTL LMA and Combitube insertion can all be practiced as well please see Using the Combitube Suction tech niques and proper cuff inflation can also be performed and evaluated Lubrication Before using the Advanced Airway Management Trainer Torso lubricate both the simulator and supplies being used with the Nasco lubricant provided See figures 1 2 Note Nasco...

Страница 5: ...then lift off the plate Disconnect the lungs from the bronchi by pulling the red caps from the white connectors See figure 6 Now that the head has been disconnect ed from the airway rotate it 180 so that it is facing backwards The large tab on the front of the neck should be aligned with the keyway in the torso Tilt the head upward until it snaps free See figure 7 Disengage the smaller rear tabs f...

Страница 6: ... with the neck slightly elevated to ensure that the solution completely fills all airway passages Once completely filled with the bleach solution allow the head to sit for at least 10 minutes Drain as described earlier and repeat the rinsing process to flush out all of the bleach solution Set the head aside and allow it to dry completely Using the Combitube Thoroughly read and follow the instruc t...

Страница 7: ...plate back over the upper compression plate and lungs 6 Reattach the chest skin by adjusting the Velcro edges Again be care ful not to damage the electronics attached to the chest skin Torso Set Up A Connecting the Airway 1 The manikin s airway has been dis connected to prevent damage dur ing shipping To connect the airway remove the chest skin chest plate compression springs and upper compression...

Страница 8: ...ators This is possible via the stan dard four lead snap cable Figure 1 If your patient simulator has only two out put posts the red and black leads must be connected to the patient simulator You may want to connect the manikin to the simulator that came with your defibrillator If your patient simulator doesn t have the standard snap connec tors it will be necessary to purchase the corresponding ad...

Страница 9: ...m the manikin Solution 1 Check your connections on the patient simulators one or more may be disconnected 2 Check to make sure your patient simulator is plugged in and working properly Problem ECG wave is inverted Solution Recheck the position of the red and black lead snaps on the patient simulator Note If the defibrillation skin is not functioning or wiring comes undone please contact us to repa...

Страница 10: ...anagement Head Only LF03609U Child Airway Management Trainer LF03610U Child Airway Management Trainer Head Only LF03611U Child Defibrillation Chest Skin LF03612U Child IV Arm LF03613U Child Blood Pressure Arm LF03614U Child Intraosseous Infusion Femoral Access Leg Only LF03615U Complete Child CRiSis Update Kit LF03616U Child CRiSis Manikin LF03617U Deluxe Child CRiSis Manikin with Arrhythmia Tutor...