Eyes

All versions of TERi

  

come with 3 sets of 

brown eyes . 1 set of 

normal pupil brown eyes, 

1 set of constricted pupil 

brown eyes and 1 set of 

dilated pupil brown eyes . 

The normal eyes come 

installed in the head . The eyes can be changed to 

dilated or constricted by creasing the skin at the 

outside of each eye and rolling the eye up . (See 

Figure 3 .) Both eyes may be irrigated using water . 

Eye sockets will hold no more than a few drops 

of liquid at a time . Following completion of the 

exercise, follow the above instructions for removing 

the eye, dry the sockets completely with  

a soft cloth, and replace the eyes .

Oral Hygiene

Tooth brushing should be simulated without water 

or any cleaning agents to avoid leaking into the 

head of the manikin and to simplify cleanup . Teeth 

cannot be flossed . Denture removal is accomplished 

by grasping the dentures and pulling forward and 

then down for the upper plate and forward then up 

for the lower plate . (See Figure 4) . Dental adhesive 

may be used . 

Note: To clean adhesive, 

use mild soap, warm 

water, and a soft cloth . 

Allow to dry completely 

before storing .

Arms / Joints

TERi

 is packaged 

with arms and female 

genitalia attached and 

legs unattached to 

prevent damage during 

shipping . Refer to the 

following sections for 

assembly instructions 

(See Figure 1) .

Note: All Versions of TERi

 come packaged with 

the normal eyes, dentures, and female genitalia 

installed . Geriatric Patient Skills Trainer and 

Simulator (LF04301, LF04302, LF04302EX) come 

with lungs, stomach, and other internal reservoir 

bags installed .

Set Up 

Arms / Joints / Legs / Eyes / Oral Hygiene

Fig 2.

Fig 4.

Fig 3.

Fig 1.

Fig 1.

Leg Assembly

The legs attach to 

the body at the 

hips by rotating 

the legs backward 

approximately 150° 

so the feet are near 

the shoulders and the 

keyholes are aligned . 

(See Figure 2) .

Содержание TERi LF04302EX

Страница 1: ...TERi Patient Care Trainer LF04300 Patient Skills Trainer LF04301 Patient Simulator LF04302 Patient Simulator Export LF04302EX INSTRUCTION MANUAL 5 Year Warranty...

Страница 2: ...y Care 13 Gastrostomy Care Lavage and Gavage 14 Male Catheterization 15 Foreskin Application Prostate Examination 16 Female Catheterization 17 Enema Administration 18 Female Cervical Exam 18 Suprapubi...

Страница 3: ...is distributed to represent a real patient for lifting and carrying Each version is affordable and durable with upgradable items Geriatric Patient Care Trainer General patient care daily living assist...

Страница 4: ...es and Female Genitalia LF4301 TERi Geriatric Patient Skills Trainer Normal and Cancerous Moles Stage 1 Sacral Ulcer Reddened Skin Folds Bandaging and Wound Dressing Recommended bandages Silicone Adhe...

Страница 5: ...ith Radial Pulse Injection Sites arms thigh right side buttocks supporting IM and sub cutaneous injections Gastrostomy Procedures lavage gavage tube placement Nasogastric Tube Procedures lavage gavage...

Страница 6: ...ursing Care Pericare Ostomy care Urinary catheter care Stomas Standard arms with injection sites Supportforoxygenadministration Leftbloodpressurearm withradialpulse Option Advanced Skills Injections s...

Страница 7: ...Suprapubic LF04334 Simulated Urine Quart PN01037 Carotid Pulse Bulb 100 2028 Syringe 20 cc Auscultation SmartScope with Batteries LF01144 Auscultation Remote with Batteries LF01148 Patient Vital Signs...

Страница 8: ...Denture removal is accomplished by grasping the dentures and pulling forward and then down for the upper plate and forward then up for the lower plate See Figure 4 Dental adhesive may be used Note To...

Страница 9: ...ubbing any painted areas of the manikin To dry the wig blot with a soft towel and air dry Do not brush the hair when wet and never use a hair dryer or blow dryer on the wig Tracheostomy Care Suctionin...

Страница 10: ...ach reservoir bag contains water to continue to prevent backflow into the head of the manikin Features included with LF04301 LF04302 and LF04302EX Fig 9 Set Up Lavage Gavage Suctioning Nasogastric Car...

Страница 11: ...op Insert the tubes back into the torso of the manikin and replace the head on the torso See Figure 16 2 Lubricate nasogastric devices and supplies being used with the Pump Spray Lubricant provided Se...

Страница 12: ...human See Figure 23 damage can be caused if improper forces and techniques are used It is not recommended to intubate with dentures installed Damaged caused by improper use will void the warranty Note...

Страница 13: ...toma reservoirs See Figure 24 1 Remove the genitalia and reach through the genital cavity It is recommended to suction the fluid from the bag prior to removal to prevent spillage when removing for cle...

Страница 14: ...he coupler body with bag attached onto the coupler insert part with the black O ring that is protruding from the underside of the gastrostomy inside the upper torso of the manikin You will hear a slig...

Страница 15: ...Fig 29 Note The Fluid Supply Stand is not included Use distilled water or follow instructions on the Simulated Urine 4 Lubricate the catheter being used with the Pump Spray Lubricant provided See Figu...

Страница 16: ...state examination Following the procedure rinse the rectum with warm water and allow to dry prior to storing Note The male genital insert does not have the capacity for enema administration Must use f...

Страница 17: ...the female genitalia to remove any residual lubricant Fluids should be drained and the reservoir emptied after every use Ensure the reservoir is clean and dry prior to storing Female Catheterization...

Страница 18: ...The enema reservoir holds up to 200cc of fluid Fig 43 Set Up Enema Administration Female Cervical Examination Features included with LF04301 LF04302 and LF04302EX The female genital insert allows for...

Страница 19: ...catheter being used with the Pump Spray Lubricant provided The catheter should be well lubricated and force should not be used when placing the tube After completion of the exercise 1 Close the clamp...

Страница 20: ...ime 2 Under the display window are three buttons Menu Gap and Calibrate Blood Pressure Arm Features included with LF04301 LF04302 and LF04302EX Installing the Batteries 1 Take the Blood Pressure Elect...

Страница 21: ...nu will display in the Electronic Control Unit window See Figure 57 6 Use the up or down arrow keys located to the right of the menu button to adjust the diastolic pressure Note The systolic and diast...

Страница 22: ...able pulse will automatically turn off when the cuff is inflated and surpasses the systolic set point It will turn on when the cuff is deflated 20 mmHg below the diastolic set point This function allo...

Страница 23: ...ar and the main menu window will be displayed Set Up Blood Pressure Arm Fig 62 Fig 63 Performing a Blood Pressure 1 Verify the pressure line tubing from the sphygmomanometer and the audio line from th...

Страница 24: ...ed with the assembled sphygmomanometer 3 Obtain a new sphygmomanometer 4 Using a scissors carefully cut the tube of the sphygmomanometer about 2 from the gauge See Figure 64 5 Take the T fitting and i...

Страница 25: ...le containing the synthetic blood concentrate with distilled water 2 Close the clamp on the IV tubing and pour the synthetic blood into one of the provided fluid supply bags This will be IV Bag A Fill...

Страница 26: ...sert IV needle or butterfly 7 To start the IV flow open the clamps on both IV Bags A and B Proof of proper procedure will be evidenced by the flow of fluid from IV Bag A Control flow rate with the cla...

Страница 27: ...rocedures and ensure clamps are open on appropriate fluid supply IV bags and or shoulder tubes 2 Look over your equipment prior to use IV tubes will kink at the clamp site with repeated use Routinely...

Страница 28: ...retaining the shoulder joint to the arm 2 Peel the skin down and remove from arm See Figure 71 3 Apply baby powder to the interior of the replacement skin and pull onto the arm 4 The key feature needs...

Страница 29: ...to prep the injection site Use distilled water to simulate this procedure Cautions 1 This synthetic blood is specially formulated to be compatible with the self sealing veins and plastics used in man...

Страница 30: ...nto SmartScope and 2 AAA batteries into the remote control The compartments are marked as to the positions of the batteries or 4 Press the red power button on the remote control This turns on the remo...

Страница 31: ...the speaker cord into the speaker jack on top of the SmartScope box 3 Plug the amplifier speaker into the 110V or 220V power source 4 When the speaker is connected the SmartScope earpieces will not w...

Страница 32: ...tolic presystolicmurmurs loud1stsound 5 Holosystolic Murmur Normal Normal Normal Normal Patienthasmitralregurgitation frequent prematureventricularcontractions Murmuriscrescendo decresendowithlate pea...

Страница 33: ...nchi Ronchi Ronchi Ronchi 8 Stridor Stridor Stridor StridorLowerVolume StridorLowerVolume 9 Cavernous Cavernous Cavernous Cavernous Cavernous 10 Bronchovesicular Tracheal Bronchovesicular NormalVesicu...

Страница 34: ...hosen opening on the foot sleeve See Figure 81 Proper Application Shown See Figure 82 Set Up Pressure Injury Wounds Set Up Edema Edema Features included with LF04301 LF04302 and LF04302EX Edema identi...

Страница 35: ...imlab heartisenseinstructor https apps apple com us app cpr add on kit instructor id1203164623 https apps apple com us app cpr add on kit student id1400115591 Powering on CPR Monitoring Feature 1 To p...

Страница 36: ...36 Set Up Consumables 36 47 37 36 38 48 45 1 7 8 22 19 15 25 35 3 31 34 63 32 4 39 55 52 53 28 29 20 50 40 42 41 49 51 30 26 12 13 18 2 62 46 21 23 11 27 4 Syringe 56 Arm Skin 9v Battery...

Страница 37: ...der Reservoir 31 LF04312 Lungs 32 LF04313 Stomach Reservoir Set Up Consumables 33 LF04314 Enema Reservoir 34 LF04315 Gastrostomy Reservoir 35 LF04316 Enema Bag 36 LF04317A Pupils Normal Set of 2 37 LF...

Страница 38: ...ure use Cautions Solvents or corrosive materials will damage the simulator Never place the simulator on any kind of printed paper or plastic These materials will transfer indelible stains Ball point p...

Страница 39: ...YEARS 5 Up to 5 years warranty...

Страница 40: ...IM 601006 10 20 2020 Nasco Healthcare...

Отзывы: