![Nasco Healthcare TERi LF04302EX Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/nasco-healthcare/teri-lf04302ex/teri-lf04302ex_instruction-manual_3365793026.webp)
26
Preparing the Arm for Intravenous Infusions
1 . Start with an “empty” unpressurized arm . Close
the clamp at the end of IV Bag A and then fill with
distilled water, 500 cc maximum . Hang IV Bag A
not more than 18” (45 .72 cm) above the arm .
2 . Ensure one of the tubes leading from the shoulder
of the Injectable Training Arm is fitted with a
clamp . Attach fitting end of IV Bag A to the
shoulder tubing with the clamp . Attach the fitting
end of IV Bag B to the remaining shoulder tube .
3 . With IV Bag B laying on the surface and IV Bag
A hanging, open the clamps on both bags and
the arm tube . Allow fluid to flow through the
Injectable Training Arm until air bubbles are
no longer seen flowing into IV Bag B . Close
the clamp on IV Bag B, the system is now
pressurized . (See Figure 69) .
Set Up
Injectable Arm
4 . Insert IV needle in vein . “Flashback” will indicate
proper insertion .
5 . After IV Bag A empties, close the clamp on
IV Bag A and the clamp on the arm tube .
Disconnect IV Bag A from the shoulder tubing .
You may now use IV Bag A as the infusion supply .
6 . Cleanse the IV site with distilled water and insert
IV needle or butterfly .
7 . To start the IV flow, open the clamps on both IV
Bags A and B .
Proof of proper procedure will be evidenced by the
flow of fluid from IV Bag A . Control flow rate with
the clamp on IV Bag A . A third IV Bag (not supplied)
can be used for the infusion of fluid . This will enable
bags A and B to remain attached to the arm .
If a more realistic experience is desired, with
“blood flashback” instead of water when inserting
the butterfly into the lumen of the vein, use the
following procedure, C .
Recommended Procedure for Simultaneous IV
Infusions and Drawing Blood
1 . Follow the procedure for setting up your IV Arm
to draw blood, Procedure A, and using IV Bag B
as the drain bag .
2 . Once the arm is pressurized and full of blood,
open the clamps on IV Bags A and B .
3 . Obtain a third IV Bag (not supplied), IV Bag C,
and ensure the clamp is closed and fill with
distilled water . Hang IV Bag C according to your
desired flow rate .
4 . Cleanse the IV site with distilled water and insert
IV needle or butterfly . A realistic blood flashback
will be evidenced with proper insertion .
5 . Connect IV Bag C to the IV needle or butterfly
with the latex connector and open the clamp to
IV Bag C . (See Figure 70) .
6 . IV Bag B, when full, may be easily switched with A .
Fig 70.
Latex Connector
Fig 69.
B
A