A. Treadstar Table
St
ag
e
Speed
(Kmph)
Grade
Rota
tions
DC Motor
Current(A)
Voltage Across
DC Motor(V)
Noise
Level
Speed
feedback
Voltage
Grade
Feedback
Voltage
w/o
load
with
load
Load
With w/o
(db)
V DC
(approx)
V DC
(approx)
1
2.7
10
14
0.5 to
1.3
2A to 3.0
21.8 23.7
66
0.21
1.18
2
4
12
21
0.5 to
1.4
1.5A to 3.0
31.6 34.5
66
0.32
1.36
3
5.5
14
28
0.5 to
1.5
1.5A to 3.5
47.7 44.5
66
0.44
1.53
4
6.8
16
34
0.5 to
1.5
2A to 3.5
50.8 53.5
66
0.54
1.71
5
8.1
18
40
0.5 to
1.6
2A to 4 A
60.8 62.4
66
0.71
1.91
6
8.9
20
44
0.5 to
1.6
2A to 4 A
65.7 68.3
66
0.71
2.1
7
9.7
22
48
0.5 to
1.7
2A to 4.5
71.7 75.6
66
0.79
2.3
B. Ac current limit to be checked with Clamp meter (See fig.1 for how to
connect clamp meter)
NOTE:-
With
load
current
can
vary
somewhat.
B) Use of Clamp meter for measurement of AC current:-
Clamp meter is used to monitor the AC current taken by AC-DC card/High frequency
Drive.
Connecting Clamp meter to measure AC current:-
1) Put the Clamp meter rotary switch in AC current measuring side at range of
200A (~)
2) Pass “Jaws” of Clamp meter through the live wire which is connected to “L” of AC-
DC card/high frequency drive by pressing the knob as shown in fig.
Stage
Speed Grade Rotati
ons
Current sensed by Clamp
meter (A)
(Kmph
)
W/o load
With load
1
2.7
10
14
0.2A-0.5 A
0.8A to
1.5A
2
4
12
21
0.3A-0.8 A
0.8A to
2.5A
3
5.5
14
28
0.3A-1A
1A to 3 A
4
6.8
16
34
0.5A-1.2A
1A to 3.5A
5
8.1
18
40
0.5 to 1.5 A 1.5A to
3.5A
6
8.9
20
44
0.5A to
1.7A
2A to 4A
7
9.7
22
48
0.5A to
1.8A
2A to 4.5A
Содержание ST WIN