background image

5

NARVON

 ATTENTION

 

 

Before any disassembly and/or cleaning procedure,  

 

make sure that the dispenser is disconnected 

 

from its power source.

FIG 1

FIG 3

FIG 2

5. CLEANING PROCEDURES

5.1 Disassembly

5.2 Cleaning

• 

The unit must be cleaned and sanitized daily in order to ensure safe and efficient operation, while guaranteeing a 

quality product.

• 

The unit does not come pre-sanitized form the factory. Before serving products, the dispenser must be disassembled, 

cleaned, and sanitized.

• 

DO NOT attempt to wash any machine components in a dishwasher.

• 

Before any disassembly and/or cleaning procedure, make sure that the dispenser is disconnected from its power source.

• 

When cleaning the machine, DO NOT allow excessive amounts of water around the electrically operated components 

of the unit. Electrical shock or damage to the machine may result.

1 . 

Empty all remaining liquid from the bowls into a container. 

DO NOT proceed without emptying the bowls.

2 . 

Remove cover from the bowl.

3 . 

Remove the empty bowl by gently pulling lever (1) and its 

front side (faucet side) up and off bowl gasket. (Fig. 1)

4 . 

Remove the bowl gasket.

5 . 

Remove the pump impeller from its location.

6 . 

Push the dispensing handle (1) and gently remove the pinch 

tube from its seat (2). (Fig. 2)

7 . 

Gently remove the piston and unfasten the dispensing tap 

assembly from the bowl. (Fig. 3)

8 . 

Slide drip tray out and empty it.

1 . 

Users should utilize the three sink method to properly clean all components:

 

a)  Fill one basin with a neutral cleaning detergent mixed in lukewarm water.

 

b)  Leave one basin empty for rinsing.

 

c)  Fill a third basin with sanitizing solution mixed in lukewarm water.

2 . 

In the first basin, Thoroughly wash all components, except the lid, in the mild cleaning detergent with a soft cloth

 

or sponge.

3 . 

Rinse all components in water.

4 . 

After rinsing, use a soft cloth or sponge to wipe down all of the components in the sanitizing solution.

5 . 

Rinse the components for a final time before leaving them out to dry.

6 . 

Wash the lids and the evaporator plates separately with a mild detergent and a soft cloth or sponge.

 

Be careful not to damage any electrical components.