6
NARVON
6. ROUTINE MAINTENANCE
6.1 Daily Maintenance
6.2 Monthly Maintenance
•
Inspect the machine for signs of product leaks past seals and gaskets. If proper assembly does not stop leaks around
seals or gaskets, check for improper lubrication, or worn or damaged parts. Replace parts as needed with original spare
parts from the supplier.
•
Clean all internal components, primarily the condenser, using compressed air.
•
To clean these internal parts, unplug the unit or switch off the 2-pole wall breaker, then remove front panel
(dispensing side). Condenser fins are very sharp, use extreme caution when cleaning.
IMPORTANT
Maintenance to be carried out by qualified service personnel only.
FIG 5
FIG 4
FIG 6
FIG 7
5.3 Assembly
1 .
Slide the drip tray back into place.
2 .
Gently fasten the bowl gasket to the evaporator.
(Fig. 4)
3 .
Place the dispensing tap back onto the bowl by
pushing the handle (1) and inserting the pinch tube
into its seat (2). Lightly pull the pinch tube downwards
until it is fully engaged (3). (Fig. 5)
4 .
Install the faucet handle and piston with its gasket.
(Fig. 6)
5 .
Gently place the bowl back on the unit by carefully
hooking the rear end back into place and then
fastening the front. (Fig. 7)