7. CONSTRUCTION OF THE STEAM ROOM:
- The steam room must be well insulated, especially the ceiling, through which most of the steam
escapes. Because of the humidity, it is recommended the insulation be covered with a moisture
resistant material, for instance aluminum foil. Wood must always be used to panel the walls.
8. PROTECTIVE BARRIER:
- A protective barrier may be built around the heater if necessary. In this case, you should
definitely adhere to the minimum clearances from structures made of flammable materials.
9. IMPORTANT ADDITIONAL INSTRUCTIONS:
- You should be careful in the vicinity of the hot heater, because the stones and
metal parts of the heater may cause burns.
- Only a small amount of water should be thrown onto the heater stones, because
the steaming water is scalding hot.
- This equipment is not to be used by children or people whose physical and
psychological traits, mental functions, lack of experience or knowledge may hinder
the safe operation of the equipment, if the person who is responsible for safety
cannot supervise them or instruct them in the use of the equipment.
- Children may not be left unsupervised and they should be supervised to make sure
they do not play with the equipment.
- Always inspect the steam room before plugging in the heater.
- The improperly filed stone container is a fire hazard.
- Covering the stove will cause a fire hazard.
When measuring the insulation barrier of the heater, some leakage may occur, which is
caused by the humidity that has seeped into the insulation material during transport
or warehousing. The moisture will evaporate after the heater is heated a few times.
Do not connect the power supply for the electric heater through a fault current protection!
10. CONNECTION SCHEME:
400V 3N~
-t
X1-2
2
3
1
4
X1-1
X1-3 X1-4
Disp.
VA1 VA2 VA3
YKS.
A1 A2
NTC
B1 B2
NTC
+12V
CTL
--
J7
J8
N
L1
L1
N
CTL L2
L2
PE
PE
L3
L3
Black
Brown
Red
Orange
Control of the electric heating
Display
NTC
Overheating
protection
Control unit
ON/OFF
Switch
Red
Yellow
Blue
White