manualshive.com logo in svg
background image

4.7 Display settings

-  In the normal operation mode of the heater, the parameters to be displayed can be selected 

  as follows: In the normal operation mode, keep the + and - buttons simultaneously depressed 

  for more than three seconds. On the display is shown ”d 1”. Now, by pressing the + and - 

  buttons one by one, you can switch between three different display modes: ”d 1”,”d 2” and ”d 3”.

  - 

”d 1”: The temperature of the sauna is shown on the display

  - 

”d 2”: The remaining power-on time is shown on the display

  - 

-”d 3”: The temperature of the sauna (the red LED is on) 

   

and the remaining power-on time (the green LED is on) are alternating on the display.

-  After having selected the display mode, return to the normal operating mode by 

  depressing the SET button.

-  If the SET button has not been depressed after the setting, ”d” and the number of the selected 

  display mode will remain on the display for about one more minute. After this, the heater will 

  automatically return to its normal operating mode, and the settings will be saved in memory.

-  The display mode setting will stay in the memory despite outage of the power.

-  During pre-timing, is always displayed the remaining preset time.

-  After failure, it is possible that one of the following two error codes is being displayed:

  - 

”E01” : Sensor circuit is open or the sensor is missing.

  - 

”E02” : The sensor is short-circuited

   

NOTE! In case of malfunction, the sauna heater will be switched off.

4.8 Examples

The desired temperature in the sauna is about 100 °C and 

the heater is desired to be switched on for 2.5 hours at a time.

1.  Switch on the power using the I/O button.

2.  Depress the SET button -> the yellow LED flashes.

3.  Depress the SET button a second time -> the green LED flashes.

4.  Depress the + or - button several times until the reading 2:30 is displayed.

5.  Depress the SET button  -> the red LED flashes.

6.  Depress the + or – button several times until the sign P14 is displayed.

7.  Depress the SET button -> the heater is switched on and the set values will be saved 

  for the next time.

You wish to switch on the heater in about three hours

1.  Switch on the power using the I/O button.

2.  Depress the SET button  -> the yellow LED flashes.

3.  Depress the + or – button several times until the reading 3:00 is displayed.

4.  Depress the SET button -> the green LED flashes.

5.  If you want to keep the set power-on time, depress the SET button; to change the power-on time,

  use the + or - buttons.

6.  After the SET button is depressed, the red LED will flash. If you wish to set the temperature, 

  you can use the + or - buttons; if not, just depress the SET button to turn the heater on.

-  Once the heater has been set, the set values will remain in memory, and when power is switched 

  on via the I/O button, the heater will always be warmed up in the same way for the same set period 

  of time. The preset time, however, will always be zero.  If you wish to apply the preset timing 

  feature, you will always need to activate it separately.

-  If the SET button is not pressed after the setting, the LED will continue flashing for about one

  minute. After this, the heater will automatically return to its normal operating mode, and the settings 

  will be saved in memory.

Содержание STONET 907230

Страница 1: ...m room space shown in table 1 Table 1 Installation information for STONET heaters The minimum height of the steam room and minimal safety clearances are shown in table 1 Make sure that the surface ont...

Страница 2: ...l the sensor in the area lined in Figure 2 Install the temperature sensor on the wall with the screws included in the delivery 2 pcs 2 9 x 16 The wiring for the temperature sensor can be embedded Conn...

Страница 3: ...an be removed to enable easier piling of the stones in the lower part When piling the stones make sure that the resistors do not get bent and that the circulation of air is sufficient Stones 5 10 cm i...

Страница 4: ...ing mode and any subsequent settings of the power on time will only affect the current heating session When the SET button is depressed the yellow LED will flash and an array of zeros will be displaye...

Страница 5: ...100 C and the heater is desired to be switched on for 2 5 hours at a time 1 Switch on the power using the I O button 2 Depress the SET button the yellow LED flashes 3 Depress the SET button a second...

Страница 6: ...ity of fresh air The fresh air is directed through a ca 100 mm diameter duct preferably directly from the outside to above the heater There must be a space of at least 1 000 mm between the temperature...

Страница 7: ...ck of experience or knowledge may hinder the safe operation of the equipment if the person who is responsible for safety cannot supervise them or instruct them in the use of the equipment Children may...