INSTALLATION AND OPERATING
INSTRUCTIONS
NARVI
STONET
6kW
907230
NARVI STONET 9kW 907232
GB
1. THE ELECTRIC HEATER SET INCLUDES:
1. Heater with control unit
2. Fastening plates and fastening screws
3. Temperature sensor
4. Control unit
5. Installation and operating instructions
2. BEFORE INSTALLATION:
Check on the following:
– Make sure the capacity of the heater (kW) corresponds to the size of the steam room (m
3
).
– Table 1 shows the heater types that correspond to various size saunas.
– If the steam room has any non-insulated brick, tile or glass surfaces, 1.5 m
3
of
space must be added to the size of the steam room for every square-meter of such
surfaces. Based on the result, choose the heater with the required capacity shown
in table 1.
When choosing a heater, strictly adhere to the steam room space shown in table 1.
Table 1. Installation information for STONET heaters
– The minimum height of the steam room and minimal safety clearances are
shown in table 1.
– Make sure that the surface onto which the fastening plates are being screwed is
sufficiently strong. Thin boarding is not sufficient. The surface can be reinforced with
a supporting framework under the boarding or reinforcing boards on top of the wall,
which is connected to a wall framework.
– The heater can also be installed into a wall recess, see figure 1.
ONLY ONE ELECTRIC HEATER MAY BE INSTALLED IN EACH SAUNA ROOM.
Stove model
Power
Sauna
Minimum safety distances for the stove Quantity of
stones
Connection*)
Volume
Height
On the
sides
At the
front
To the
ceiling
From
the
floor
400 V 3N
Fuses
min max
min
A **)
B **)
C **)
D **)
kW
m
3
m
3
cm
cm
cm
cm
cm
kg
mm
2
A
STONET
907230
6
5
8
190
3
25
100
3
60
5x1,5
3x10
STONET
907232
9
8
14
190
5
25
100
3
60
5x2,5
3x16
**) See figure 1
*) Use a rubber cable, H07RN-F or similar cable