2. Regulating the time and temperature
• it is regulated using the +/- buttons, when the corresponding function is displayed.
4.2 Meaning of the signal lights
5. Green signal light = is on when the temperature measured in the steam
room is displayed.
6. Yellow signal light = is on when the pre-selection time is displayed.
Flashes when the pre-selection time is displayed.
7. Red signal light = is on when the chosen temperature is achieved for the first time.
4.3 Error messages
• ERR1 = interruption in the sensor
power circuit.
• ERR2 = short in the sensor power circuit.
• ERR3 = interruption in the power circuit for
the overheating protection
(the reset button on the sensor
turns off the overheating protection).
ATTENTION! If an error appears turn off the stove!
5. TECHNICAL DATA
5.1 Upper card
• protection class
IPX4
• control console may be
installed in the sauna or
dressing room
4.4. Technical data
• Temperature regulating 40–115 °C
• Temperature screen 20-115 °C
• Steps by 1°C
• Pre-selection time max. 24 h
• Steps
By 0-1 h 15 min
By 1-24 h 30 min
• Max. pre-selection time 4 h
5.2 Lower card
• voltage
230 V 3N 50 Hz
• amperage
16 A
• stove capacity
max 9 kW
• protection class
IPX4
• overheating protection 144ºC
• protection
1 A
6. AIR EXCHANGE FOR THE STEAM ROOM:
- The air exchange in the steam room must be as efficient as possible, in order to
guarantee sufficient oxygen content and availability of fresh air.
- The fresh air is directed through a ca. 100-mm diameter duct preferably directly
from the outside to the above the stove.
- There must be a space of at least 1,000 mm between the SENSOR and the fresh air
duct or 500 mm if the duct end can be turned.
- The fresh air can also be directed close to the stove; to the side and underneath.
- It is important to introduce fresh air, so that the air mixes with the air and the steam.
- The exiting air should be exhausted as far as possible from the incoming air.
- The air exhaust valve may be located under the sauna benches.
- The exiting air may be directed out of the steam room through the washroom,
for instance under the door. There must be an approximately 100-150-wide slit
between the door and the floor.