PMM SET ADDRESS Instructions for use

 

 

 

 

3.3 Hardware installation 

The PMM SB-10 Switching Control Box works  in conjunction with various 
device in a wide range of frequencies and levels. 
The examples  in the Chapter 2 show the connection of PMM SB10 with 
Personal Computer,  PMM  OR03  Programmable  Optical Repeater and its 
probes, and PMM EP600/601/602/603.

 

 

PMM SB10 allows  the user to take field measurements with up to 10 
device, connected at the same time, placed at different measuring locations 
and/or working on different frequencies,  and full scale ranges by using a 
single RS232 port to the PC.

 

 

After having completed the setup, run the PMM SET ADDRESS Utility.

 

 

 
 

 

3.4 To run the program 

To run the utility double click on the 

Setadd53.exe 

icon  

 

 

3.5 To start the program 

In case the PMM SB10 or PMM OR03 are OFF or they are not connected 
properly  or the serial port is wrong or the communication is not correct an 
error message window will be displayed: 
 

 

 

 

 

Once the connection is established

,

 the main window will be displayed: 

 

 

Содержание PMM SB-10

Страница 1: ...erial Number in a side of the box Serial Number is in the form 0000X00000 The first four digits and the letter are the Serial Number prefix the last five digits are the Serial Number suffix The prefix...

Страница 2: ...AFETY SYMBOLS You now own a high quality instrument that will give you many years of reliable service Nevertheless even this product will eventually become obsolete When that time comes please remembe...

Страница 3: ...Introduction 2 1 2 2 Initial inspection 2 1 2 3 Environment 2 1 2 4 Return for service 2 1 2 5 Equipment cleaning 2 1 2 6 PMM SB 10 Installation and use 2 2 2 7 External DC supply 2 3 2 8 Installation...

Страница 4: ...Figure Page 1 1 PMM SB 10 front panel 1 3 1 2 PMM SB 10 rear panel 1 3 2 1 Single SB 10 installation example 2 2 2 2 Multiple SB 10 installation example 2 2 Tables Table Page 1 1 PMM SB 10 Technical...

Страница 5: ...In case of connection of the device to the power mains make sure before connection that the voltage selected on the voltage switch and the fuses are adequate for the voltage of the actual mains Devic...

Страница 6: ...arda Safety Test Solutions S r l Via Benessea 29 B 17035 Cisano sul Neva SV ITALY complies with the following European Standards Safety CEI EN 60950 CEI EN 60950 A4 CEI EN 60950 A11 EMC EN 61326 1 EN...

Страница 7: ...fferent measuring points and or working on different frequency and full scale ranges it is possible to have a chain up to five SB 10 to connect up to 50 remote devices The PMM SB 10 is powered by an E...

Страница 8: ...00 kHz 3 GHz 1 1000 V m Electric Field Probe EP 333 100 kHz 3 6 GHz 0 15 300 V m Electric Field Probe EP 183 1 MHz 18 GHz 0 8 800 V m Electric Field Probe EP 408 1 MHz 40 GHz 0 8 800 V m Electric Fiel...

Страница 9: ...vice 5 Fiber optic connector 7 Device 6 Fiber optic connector 8 Device 7 Fiber optic connector 9 Device 8 Fiber optic connector 10 Device 9 Fiber optic connector 11 Device 10 Fiber optic connector 1 7...

Страница 10: ...1 4 General Information This page has been left blank intentionally...

Страница 11: ...ative The instrument should be stored and shipped in a clean dry environment which is specified to be within the following limitations Temperature Humidity 20 to 70 C 95 relative 2 5 Return for servic...

Страница 12: ...10 Switching Control Box can function together with several NARDA isotropic probes with a wide frequency and level operating range The following figure shows an example of SB 10 interconnection Fig 2...

Страница 13: ...y the PC USB port 2 9 Installation To install the PMM SB 10 simply connect the provided optical fiber to the DEVICE X connector on the front panel taking care of the insertion key then connect the oth...

Страница 14: ...2 4 Installation This page has been left blank intentionally...

Страница 15: ...ral PMM EP600 EP601 EP602 EP603 are connected to the PMM SB 10 and each of them need to be set with a different address it is suggested to use the utility SetAddEP600 provided with the probe self Plea...

Страница 16: ...h up to 10 device connected at the same time placed at different measuring locations and or working on different frequencies and full scale ranges by using a single RS232 port to the PC After having c...

Страница 17: ...the device connected to the SB 10 Address It shows the address that must be assigned at the device connected at the SB10 the address range is from 00 to 10 Reading Status It shows the current process...

Страница 18: ...cess the software shows the Release and Date of the device connected to the SB 10 The default address of each device is 00 and the utility will show the message ADDRESS received 00 To change the addre...

Страница 19: ...ike to submit to the attention of our service organization is kept in great consideration Moreover we are continuously improving our quality but we know this is a never ending process We would be glad...

Страница 20: ...Suggerimenti Commenti Note Suggestions Comments Note...

Отзывы: