2.1 Main specifications
Table 2-1 lists the PMM L3-32 Network performance specifications.
The following conditions apply to all specifications:
•
The ambient temperature must be -10° to 40°.
TABLE 2-1 Main specifications PMM L3-32
Frequency range:
Maximum continuous rated output current:
Maximum operating voltage
Single-phase (L/N) (L/PE) (N/PE):
Three-phase (L/PE) (N/PE):
(L/L) (L/N):
Input Mains frequency range:
Equivalent circuit:
RF output:
Test item:
Rated temperature:
Storage temperature:
Overall dimension mm (W x H x D):
Weight:
9 kHz to 30 MHz
IEC plug: 32 A
Schuko plug: 16 A
230 Vac 325 Vdc
230 Vac 325 Vdc
400 Vac 565 Vdc
DC - 60 Hz
50 Ohm // (5 Ohm + 50
µ
H)
BNC female
32 A IEC connector and 16A Schuko
-10° to + 40° C
-25° to + 75° C
342 x 254 x 510
16.5 kg