8.0 optional blower installation
VARIABLE SPEED
SWITCH LOCATION
CONTROL
PANEL
THERMAL
DISK
ASSEMBLY
BLOWER
ASSEMBLY
SUPPORT
BRACKET
SEE-THR
U W
IND
OW
CLIP
RED
BLACK
THERMAL SWITCH
VARIABLE SPEED SWITCH
BLOWER
WIRE
HARNESS
(included in GS66 kit)
WHITE
TO POWER SUPPLY
WHITE
GS66 WIRING DIAGRAM
VARIABLE
SPEED SWITCH
KNOB
ROUGE
NOIR
INTERRUPTEUR THERMIQUE
INTERRUPTEUR À VITESSE VARIABLE
SOUFFLERIE
HARNAIS
DE FILS
(inclus avec l’ensemble GS66)
BLANC
À L’ALIMENTATION
ÉLECTRIQUE
BLANC
SCHÉMA DE CÂBLAGE DU GS66
BOUTON DE CONTRÔLE
DE VITESSE VARIABLE
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be connected and
grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the current ANSI/NFPA 70 National Electrical Code in the United States.
If an optional blower is to be used, the blower must be connected to the main power supply. Route a grounded 14
gauge 2-wire power cable to the junction box and ground. At the point where the cable enters the junction box, a
conduit connector must be provided.
A.
Remove the two screws that secure the control panel to the front of the appliance.
B.
Connect the black and red wires of the wire harness to the prongs on the blower.
C.
Connect the white and black wires of the wire harness to the prongs on the
thermodisc.
D.
Place the thermal switch assembly onto
the stud located at the lower left of the
firebox and behind the support bracket.
E.
Connect the wiring for the variable speed
switch.
F.
Insert the blower assembly into the left
side under the firebox, slide into
the clip and place onto the same
stud used for the thermal switch
assembly. Secure with the lock
washer and wing nut supplied.
Ensure that the blower does not
touch the base of the firebox, any
wiring or controls. Ensure that the
thermal switch is touching the wall
of the firebox.
G.
Plug into the receptacle on the
right side of the appliance.
H.
Place the variable speed switch
into position and secure with the
pal nut supplied. Reinstall the
control panel and install the variable
speed switch knob.
!
WARNING
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan’s power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
35.1
SPECIFIC BLOWER INSTALLATION
INSTRUCTIONS MUST BE ADDED HERE.
THIS TEMPLATE MUST BE USED WITH ANY
APPLIANCE THAT OFFERS THE BLOWER AS
AN OPTION OR COMES STANDARD WITH THE
APPLIANCE... AS PER THE STANDARD.
Rest the thermal disk assembly forward
against the firebox.
hint:
Variable Speed
Switch Location
Control Panel