W415-2350 / 10.28.19
EN
10
venting
MIN
MAX
Allowable 3/5 vent connections (excluding appliance and air terminal connections)
N/A
1
Rise per foot (recommended)
1/4"
(6.4mm)
N/A
Rise per foot (allowable)
0”
N/A
Horizontal run (If vent run does not include vertical rise)
4" (102mm)
24"
(610mm)
Horizontal run (if vent run includes vertical rise)
4" (102mm)
7' (2m)
Vertical run
(* Immediately off the appliance, if 7' (2m) maximum horizontal run is required)
18"
(457mm)*
7' (2m)
0
1 2 3 4 5 6 7 8 9 10
10
9
8
7
6
5
4
3
2
1
1.5
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (
H
T
)
REQUIRED
VERTICAL
RISE IN
FEET (
V
T
)
See graph to determine the required vertical rise
V
T
for the required horizontal rise
H
T
.
4" (102mm)
MIN.
24" (610mm)
MAX.
8"
(457mm)
18"
(457mm)
MAXIMUM
HORIZONTAL
7' (2m) MAX.
4"
(102mm)
MIN.
8"
(457mm)
9'
(2.7m)
MAX.
MAXIMUM
VERITICAL
4"
(102mm)
MIN.
Any offsets other than 2-90° elbows used in the vent run - must be deducted from the maximum horizontal vent
run based upon the offset value.
2.4 horizontal