background image

18

W415-0434 / C / 03.24.05

Glowing embers (not supplied) maybe used to enhance
the flame's appearance.

4.

 Place log #4, with the charred branch pointed inward.

Locate the pins into the holes in log#1 and log#2, this will
hold the rear log in position.

5.

 Place the end of log #5 on the right end of log #1. The

fork in the log should straddle the knot on top of log #2.

GLOWING EMBERS

BAFFLE INSTALLATION

CHARCOAL EMBERS

PHAZER

TM

 logs, exclusive to Napoleon Fireplaces, pro-

vide a unique and realistic glowing effect that is different in
every installation.

1.

 Centre the two charcoal strips, as shown, along the

inside front edge of the firebox.
Place the rear log #1 onto the locating studs along the
back edge of the PHAZERAMIC™ burner.

2.

 Position log #2 onto the locators on the PHAZERAMIC™

burner.

3.

 Position log #3 onto the right most grate rail with the

charred face to the front. Align the groove on the underside
of the log, with the rail of the grate. Push the log back to the
pilot housing. Log #3 should fit tight against log #2.

LOG PLACEMENT

2

3

4

FIGURES 46a-e

1

CHARCOAL STRIPS

5

Your fireplace has been supplied with the decorative  brick
panels installed. It will be necessary, however, to install the
fibre baffle, on top of the side and rear panels.

Charcoal provided should be randomly placed in the trian-
gular trays on either side of the of the burner.

Log colour

Log colour

Log colour

Log colour

Log colours

s

s

s

s

     

ma

ma

ma

ma

may v

y v

y v

y v

y vary

ary

ary

ary

ary. During the initial use of

. During the initial use of

. During the initial use of

. During the initial use of

. During the initial use of  the f

 the f

 the f

 the f

 the fir

ir

ir

ir

ire-

e-

e-

e-

e-

place, the colours will become more uniform as colour

place, the colours will become more uniform as colour

place, the colours will become more uniform as colour

place, the colours will become more uniform as colour

place, the colours will become more uniform as colour
pigments burn in during the heat activated curing pro-

pigments burn in during the heat activated curing pro-

pigments burn in during the heat activated curing pro-

pigments burn in during the heat activated curing pro-

pigments burn in during the heat activated curing pro-
cess

cess

cess

cess

cess.....

Positioning the logs improperly will cause flame im-
pingement and carboning.

Blocked burner ports can cause an incorrect flame pattern,
carbon deposits and delayed ignition. 

PHAZER

TM

 logs glow

when exposed to direct flame. Use only certified 

PHAZER

TM

logs available from your Napoleon dealer.

Содержание StarFire GD70NT-S

Страница 1: ...88 FOR VENTED GAS FIREPLACE HEATERS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR S...

Страница 2: ...and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It i...

Страница 3: ...ranty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanic...

Страница 4: ...an only be installed in a mobile home that is permanently positioned on its site and fueled with natural gas WARNING The door for this fireplace is sold separately The door must be installed and close...

Страница 5: ...hat all horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise p...

Страница 6: ...h formulas are met this vent configuration is ac ceptable FIGURE5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT...

Страница 7: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4ft V2 1 5ft VT V1 V2 4 1 5 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft...

Страница 8: ...or HT and VT when HT VT Simple venting configurations FIGURE 9 For vent configurations requiring more than zero 90 elbow top exit or one 90 elbow rear exit the following formu las apply Formula 1 HT V...

Страница 9: ...8 1 ft HT HR HO 8 8 1 16 1 ft HT VT 16 1 4 5 20 6 ft Formula 1 HT 3VT 3VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 feet 20 6...

Страница 10: ...pen Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to u...

Страница 11: ...he air terminal FIGURE13 INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL INSTALLATION VERTICAL INSTALLATION FIGURE17 FIGURE16 FIGURE15 For optimum performance it is recommended that all horizontal...

Страница 12: ...oof support to the roof using the screws pro vided The roof support is optional In this case the venting is to be ad equately supported us ing either an alternate method suitable to the authority havi...

Страница 13: ...e 7 inch diameter alu minum flexible liner to the fireplace Attach and seal the joints For optimum performance it is recommended that all horizontal runs have a inch rise per foot For safe and proper...

Страница 14: ...me pattern and creat ing a more traditional appearance 1 Remove all obstructing obsta cles i e brick panels logs etc 2 Remove the baffle plate from the rear wall of the firebox exposing the two screws...

Страница 15: ...d wall position the framework to accomodate the thickness of the finished wall MAINTAIN THESE MINIMUM CLEARANCES TO COM BUSTIBLES Fireplace framing 0 to stand offs top rear sides Fireplace finishing 3...

Страница 16: ...the hinge screen into place and with the control door open secure to the firebox using three screws Remove the pro tective plastic wrap from the louvres and install as illus trated Clip each upper lo...

Страница 17: ...he louvre tabs into the slots located at the top left and right corners of the unit A CLIPS CENTRE SLOT FLANGE SLOT TAB B C HINGE CLIP SLOT Before installing the logs you must first remove the log shi...

Страница 18: ...be necessary however to install the fibre baffle on top of the side and rear panels Charcoal provided should be randomly placed in the trian gular trays on either side of the of the burner Log colour...

Страница 19: ...he four screws that secure the lens frame This frame retains the glass lens The lamp can now be accessed Note Note Note Note Note Do not handle the lamp bulb with bare fingers Do not handle the lamp b...

Страница 20: ...ng contact with any mo mo mo mo moving or hot objects ving or hot objects ving or hot objects ving or hot objects ving or hot objects Drywall dust will penetrate into the blower bearings Drywall dust...

Страница 21: ...ng Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de partment WARNING The gas valve has an inter...

Страница 22: ...obstructed 1 In order to properly clean the burner and pilot assem bly remove the logs to expose both assemblies 2 Keep the control compartment logs burner air shut ter opening and the area surroundi...

Страница 23: ...LOUVRE KIT BLACK 59 GDLVG UPPER LOWER LOUVRE KIT GOLD 60 L38K LOUVRE KIT UPPER LOWER BLACK 60 L38AB LOUVRE KIT UPPER LOWER ANTIQUE BRASS 60 L38PB LOUVRE KIT UPPER LOWER POLISHED BRASS 60 L38SS LOUVRE...

Страница 24: ...24 W415 0434 C 03 24 05 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 25: ...me pattern around the thermocouple Pilot flame is not engulfing the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocoup...

Страница 26: ...sulation is broken or frayed replace the electrode if the ceramic insulator is cracked or broken replace the push button ignitor No spark at pilot burner fill the tank Out of propane gas Spark gap is...

Страница 27: ...27 W415 0434 C 03 24 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 28: ...28 W415 0434 C 03 24 05 NOTES...

Отзывы: