background image

23

W415-0434 / C / 03.24.05

#

PART NO. DESCRIPTION

1

W135-0205

#1 - REAR LOG

2

W135-0206

#2 - MIDDLE LOG

3

W135-0207

#3 - RIGHT LOG

4

W135-0208

#4 - LEFT LOG

5

W135-0218

#5 - CROSSOVER LOG

6

GL-644

LOG SET ASSEMBLY

7*

W090-0095

L CHARCOAL STRIP

8*

W090-0096

R CHARCOAL STRIP

9*

W390-0002

DOOR LATCH (

EA

)

10

W725-0025

NATURAL GAS VALVE

10

W725-0026

PROPANE GAS VALVE

11*

W380-0010

PILOT ON/OFF KNOB EXTENSION

12* W380-0011

FLAME ADJUSTMENT KNOB EXTENSION

13

W455-0058

#35 NATURAL GAS ORIFICE

13

W455-0051

#51 PROPANE GAS ORIFICE

14

W357-0001

PIEZO IGNITER

15

W680-0005

THERMOCOUPLE

16

W240-0005

ELECTRODE

C

/

W

 LEAD

17

W680-0004

THERMOPILE

18

W010-0801

NATURAL GAS PILOT ASSEMBLY

18

W010-0800

PROPANE GAS PILOT ASSEMBLY

19

W455-0070

NG PILOT INJECTOR

19

W455-0068

LP PILOT INJECTOR

20* W385-0245

NAPOLEON LOGO

21* W361-0027

INSULATION SLEEVE

22* W010-0621

GLASS

C

/

W

 GASKET

23* W562-0009

DOOR GASKET (100 INCHES)

24* W500-0106

FIRESTOP (2 INCH CLEARANCE)

25

W010-1135

BURNER ASSEMBLY

26* W200-0146

COVER PLATE

27* W290-0080

COVER PLATE GASKET

28

W062-0005

BLOWER

29

W690-0002

THERMODISC

30* W750-0050

BLOWER WIRE

31* W660-0019

VARIABLE SPEED SWITCH

32* W300-0067

FIRE LOG ACCENT LIGHT GLASS

33* W387-0006

ACCENT LAMP

34* W750-0107

FIRE LOG ACCENT LIGHT WIRE

35* W290-0080

ACCENT LENSE GASKET

36* W500-0130

RESTRICTOR PLATE

GD-220 (5 FOOT)

44

W010-0397

4" FLEXIBLE ALUMINUM LINER 

C

/

W SPACERS

45

W410-0017

7" FLEXIBLE ALUMINUM LINER

GD-330 (10 FOOT)

44

W010-0300

4" FLEXIBLE ALUMINUM LINER 

C

/

W SPACERS

45

W410-0018

7" FLEXIBLE ALUMINUM LINER

52

W010-0370

WALL SUPPORT ASSEMBLY

#

PART NO. DESCRIPTION

46

W615-00044

FIRE STOP - FLEXIBLE VENTING

46

W500-0136

FIRESTOP - RIGID VENTING

47

W500-0103

TERMINAL EXTENSION PLATE

48* W573-0008

HI-TEMP SEALANT

49

GD101

WINDSHIELD KIT

50

GD301

HEAT GUARD

51

GA-566

HOT AIR DISTRIBUTION KIT

52

GA-72

HOT AIR EXHAUST KIT

53

GA-70

EXTENSION KIT, 5FT FLEX VENT

54* W010-0370

WALL SUPPORT ASSEMBLY

55* W175-0001

4" COUPLER

56* W175-0013

7" COUPLER

57* W175-0221

CONVERSION KIT - 

NG TO LP

57* W175-0222

CONVERSION KIT - 

LP TO NG

58* GD825-N

MODULATING REGULATOR  

NG

58* GD825-P

MODULATING REGULATOR  

LP

59

GDLVPB

UPPER & LOWER LOUVRE KIT - 

POLISHED BRASS

59

GDLVSS

UPPER & LOWER LOUVRE KIT - 

STAINLESS STEEL

59

GDLVK

UPPER & LOWER LOUVRE KIT - 

BLACK

59

GDLVG

UPPER & LOWER LOUVRE KIT - 

GOLD

60

L38K

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

BLACK

60

L38AB

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

ANTIQUE BRASS

60

L38PB

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

POLISHED BRASS

60

L38SS

LOUVRE KIT - 

UPPER

 & 

LOWER

 - 

STAINLESS STEEL

61

KB35

VARIABLE SPEED SWITCH

62* W500-0033

V.S.S. MOUNTING PLATE  

FOR WALL SWITCH

63* W690-0001

MILLIVOLT THERMOSTAT

64* W690-0005

110 VOLT THERMOSTAT - 

FOR USE WITH GA

-566

65

D70K

BLACK DOOR

65

D70G

GOLD PLATED DOOR

65

D70SS

STAINLESS STEEL DOOR

66* GD427-K

BLACK DOOR KIT 

C

/

W

 FACEPLATE

67* W573-0007

10.3OZ TUBE HIGH TEMP SEALANT MILL PAC

68

GD799-KT

OLD TOWN RED BRICK KIT

68

GD804-KT

SANDSTONE BRICK KIT

68

GD805-KT

HERRINGBONE/SANDSTONE BRICK KIT

68

PRP70

PORCELAIN REFLECTIVE PANELS BRICK KIT

Contact your dealer for questions concerning prices and
availability of replacement parts. Normally all parts can be
ordered through your Napoleon dealer or distributor.
When ordering replacement parts always give the follow-
ing information:

1.  M

ODEL

 & S

ERIAL

 N

UMBER OF FIREPLACE

2.  I

NSTALLATION DATE OF FIREPLACE

3.  P

ART

 N

UMBER

4.  D

ESCRIPTION OF PART

5.  F

INISH

FOR

FOR

FOR

FOR

FOR

     

WARRANTY

WARRANTY

WARRANTY

WARRANTY

WARRANTY

     

REPL

REPL

REPL

REPL

REPLA

A

A

A

ACEMENT

CEMENT

CEMENT

CEMENT

CEMENT

     

P

PP

PPAR

AR

AR

AR

ARTS

TS

TS

TS

TS

, , , , , 

A

A

A

A

A

     

PHO

PHO

PHO

PHO

PHOTTTTTOCOPY

OCOPY

OCOPY

OCOPY

OCOPY

     

OF

OF

OF

OF

OF

     

THE

THE

THE

THE

THE

ORIGINAL

ORIGINAL

ORIGINAL

ORIGINAL

ORIGINAL

     

INVOICE

INVOICE

INVOICE

INVOICE

INVOICE

     

WILL

WILL

WILL

WILL

WILL

     

BE

BE

BE

BE

BE

     

REQUIRED

REQUIRED

REQUIRED

REQUIRED

REQUIRED

     

TO

TO

TO

TO

TO

     

HONOUR

HONOUR

HONOUR

HONOUR

HONOUR

     

THE

THE

THE

THE

THE

     

CLAIM

CLAIM

CLAIM

CLAIM

CLAIM

.....

REPLACEMENTS

IDENTIFIES

 

ITEMS

 

WHICH

 

ARE

 

NOT

 

ILLUSTRATED

FOR

FURTHER

 

INFORMATION

CONTACT

 

YOUR

 

NAPOLEON

DEALER

.

REPLACEMENT PARTS

VENT KITS

ACCESSORIES

TERMINAL KITS

42

GD-201  -  PERISCOPE

43

GD-222 - WALL TERMINAL KIT

ROOF TERMINAL KITS

GD-110  -  ROOF TERMINAL KIT - 1/12 TO 7/12 PITCH

37

W120-0036

VERTICAL CAP

38

W010-0569

AIR TERMINAL

39

W010-0567

ROOF SUPPORT

40

W170-0063

STORM COLLAR

41

W263-0054

ROOF FLASHING

GD-111  -  ROOF TERMINAL KIT - 8/12 TO 12/12 PITCH

37

W120-0036

VERTICAL CAP

38

W010-0569

AIR TERMINAL

39

W010-0567

ROOF SUPPORT

40

W170-0063

STORM COLLAR

41

W263-0055

ROOF FLASHING

GD-112  -  ROOF TERMINAL KIT - FLAT ROOF

37

W120-0036

VERTICAL CAP

38

W010-0569

AIR TERMINAL

39

W010-0567

ROOF SUPPORT

40

W170-0063

STORM COLLAR

41

W263-0056

ROOF FLASHING

Содержание StarFire GD70NT-S

Страница 1: ...88 FOR VENTED GAS FIREPLACE HEATERS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR S...

Страница 2: ...and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It i...

Страница 3: ...ranty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanic...

Страница 4: ...an only be installed in a mobile home that is permanently positioned on its site and fueled with natural gas WARNING The door for this fireplace is sold separately The door must be installed and close...

Страница 5: ...hat all horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise p...

Страница 6: ...h formulas are met this vent configuration is ac ceptable FIGURE5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT...

Страница 7: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4ft V2 1 5ft VT V1 V2 4 1 5 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft...

Страница 8: ...or HT and VT when HT VT Simple venting configurations FIGURE 9 For vent configurations requiring more than zero 90 elbow top exit or one 90 elbow rear exit the following formu las apply Formula 1 HT V...

Страница 9: ...8 1 ft HT HR HO 8 8 1 16 1 ft HT VT 16 1 4 5 20 6 ft Formula 1 HT 3VT 3VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 feet 20 6...

Страница 10: ...pen Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to u...

Страница 11: ...he air terminal FIGURE13 INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL INSTALLATION VERTICAL INSTALLATION FIGURE17 FIGURE16 FIGURE15 For optimum performance it is recommended that all horizontal...

Страница 12: ...oof support to the roof using the screws pro vided The roof support is optional In this case the venting is to be ad equately supported us ing either an alternate method suitable to the authority havi...

Страница 13: ...e 7 inch diameter alu minum flexible liner to the fireplace Attach and seal the joints For optimum performance it is recommended that all horizontal runs have a inch rise per foot For safe and proper...

Страница 14: ...me pattern and creat ing a more traditional appearance 1 Remove all obstructing obsta cles i e brick panels logs etc 2 Remove the baffle plate from the rear wall of the firebox exposing the two screws...

Страница 15: ...d wall position the framework to accomodate the thickness of the finished wall MAINTAIN THESE MINIMUM CLEARANCES TO COM BUSTIBLES Fireplace framing 0 to stand offs top rear sides Fireplace finishing 3...

Страница 16: ...the hinge screen into place and with the control door open secure to the firebox using three screws Remove the pro tective plastic wrap from the louvres and install as illus trated Clip each upper lo...

Страница 17: ...he louvre tabs into the slots located at the top left and right corners of the unit A CLIPS CENTRE SLOT FLANGE SLOT TAB B C HINGE CLIP SLOT Before installing the logs you must first remove the log shi...

Страница 18: ...be necessary however to install the fibre baffle on top of the side and rear panels Charcoal provided should be randomly placed in the trian gular trays on either side of the of the burner Log colour...

Страница 19: ...he four screws that secure the lens frame This frame retains the glass lens The lamp can now be accessed Note Note Note Note Note Do not handle the lamp bulb with bare fingers Do not handle the lamp b...

Страница 20: ...ng contact with any mo mo mo mo moving or hot objects ving or hot objects ving or hot objects ving or hot objects ving or hot objects Drywall dust will penetrate into the blower bearings Drywall dust...

Страница 21: ...ng Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de partment WARNING The gas valve has an inter...

Страница 22: ...obstructed 1 In order to properly clean the burner and pilot assem bly remove the logs to expose both assemblies 2 Keep the control compartment logs burner air shut ter opening and the area surroundi...

Страница 23: ...LOUVRE KIT BLACK 59 GDLVG UPPER LOWER LOUVRE KIT GOLD 60 L38K LOUVRE KIT UPPER LOWER BLACK 60 L38AB LOUVRE KIT UPPER LOWER ANTIQUE BRASS 60 L38PB LOUVRE KIT UPPER LOWER POLISHED BRASS 60 L38SS LOUVRE...

Страница 24: ...24 W415 0434 C 03 24 05 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 25: ...me pattern around the thermocouple Pilot flame is not engulfing the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocoup...

Страница 26: ...sulation is broken or frayed replace the electrode if the ceramic insulator is cracked or broken replace the push button ignitor No spark at pilot burner fill the tank Out of propane gas Spark gap is...

Страница 27: ...27 W415 0434 C 03 24 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 28: ...28 W415 0434 C 03 24 05 NOTES...

Отзывы: