background image

21

W415-0434 / C / 03.24.05

A.

 This fireplace is equipped with a pilot which must be
lit by hand while following these instructions exactly.

B.

 Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.

C.

 Use only your hand to turn the gas control knob. Never

use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or
attempted repair may result in a fire or explosion.

D.

Do not use this fireplace if any part has been under

water. Immediately call a qualified service technician to
inspect the fireplace and replace any part of the control
system and any gas control which has been under wa-
ter.

GAS KNOB

When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the curing of the logs and the "burn-in" of
internal paints and lubricants used in the manufacturing
process and will not occur again. Simply open a window to
sufficiently ventilate the room.

After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles in the heat exchanger burning off. Open a window
to sufficiently ventilate the room.

PURGE ALL GAS LINES WITH THE GLASS DOOR OF

THE FIREPLACE OPEN. ASSURE THAT A CONTINU-

OUS GAS FLOW IS AT THE BURNER BEFORE

CLOSING THE DOOR.

• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier from a neighbour's

phone. Follow the gas supplier's instructions.

• If you cannot reach your gas supplier, call the fire de-

partment.

WARNING: 

The gas valve has an interlock device which

will not allow the pilot burner to be lit until the thermo-
couple has cooled. Allow approximately 60 seconds for
the thermocouple to cool.
When lighting and re-lighting, the gas knob cannot be
turned from pilot to off unless the knob is 

depressed

slightly.
1.

Stop! Read the above safety information on this label.

2.

Turn off all electric power to the fireplace.

3.

Turn the gas knob clockwise 

 to off.

4.

Wait five (5) minutes to clear out any gas. If you smell

gas including near the floor. Stop! Follow "B" in the
above safety information on this label. If you don't smell
gas go the next step.

5.

 Turn gas knob counter-clockwise 

  to pilot.

6.

 Depress slightly and hold gas knob while lighting the

pilot with the push button ignitor. Keep knob depressed
for one minute, then release. If pilot does not con tinue
to burn, repeat steps 3 through 5.

7.

 With pilot lit, depress and turn gas knob counter-clock

wise

 to on.

8.

 If equipped with remote on-off switch/thermostat, main

burner may not come on when you turn valve to on.
Remote switch must be in the on position to ignite
burner.

9.

Turn on all electric power to the fireplace.

1.

Turn off all electric power to the fireplace if service is to

be performed.

2.

 For a complete shut-down procedure: push in gas con-

trol knob slightly and turn clockwise

 to off. Do not

force.

3.

 For a temporary shut-down procedure: set thermostat

to lowest setting or remote switch to off. Press and turn
the gas knob clockwise 

 to pilot.

OPERATION / MAINTENANCE

OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING:

LIGHTING INSTRUCTIONS

TO TURN OFF GAS

WHAT TO DO IF YOU SMELL GAS

FIGURE 55

FIGURE 56

Содержание StarFire GD70NT-S

Страница 1: ...88 FOR VENTED GAS FIREPLACE HEATERS WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death FOR YOUR S...

Страница 2: ...and draperies Clothing or other flammable material should not be placed on or near the fireplace Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It i...

Страница 3: ...ranty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanic...

Страница 4: ...an only be installed in a mobile home that is permanently positioned on its site and fueled with natural gas WARNING The door for this fireplace is sold separately The door must be installed and close...

Страница 5: ...hat all horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise per foot horizontal runs have a minimum inch rise p...

Страница 6: ...h formulas are met this vent configuration is ac ceptable FIGURE5 90 H1 V2 H2 V1 HORIZONTAL VENT RUN PLUS OFFSET IN FEET HT The shaded area within the lines represents acceptable values for HT and VT...

Страница 7: ...1 HT 4 2 VT Formula 2 HT VT 24 75 feet Example 2 Example 3 V1 4ft V2 1 5ft VT V1 V2 4 1 5 5 5 ft H1 2ft H2 1ft H3 1ft H4 1 5ft HR H1 H2 H3 H4 2 1 1 1 5 5 5 ft HO 03 four 90 elbows 90 03 360 90 8 1 ft...

Страница 8: ...or HT and VT when HT VT Simple venting configurations FIGURE 9 For vent configurations requiring more than zero 90 elbow top exit or one 90 elbow rear exit the following formu las apply Formula 1 HT V...

Страница 9: ...8 1 ft HT HR HO 8 8 1 16 1 ft HT VT 16 1 4 5 20 6 ft Formula 1 HT 3VT 3VT 3 x 4 5 13 5 ft 16 1 13 5 Since this formula is not met this vent configuration is unacceptable Formula 2 HT VT 40 feet 20 6...

Страница 10: ...pen Clearance to permanently closed windows Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal Clearance to u...

Страница 11: ...he air terminal FIGURE13 INSTALLATION WALL AND CEILING PROTECTION HORIZONTAL INSTALLATION VERTICAL INSTALLATION FIGURE17 FIGURE16 FIGURE15 For optimum performance it is recommended that all horizontal...

Страница 12: ...oof support to the roof using the screws pro vided The roof support is optional In this case the venting is to be ad equately supported us ing either an alternate method suitable to the authority havi...

Страница 13: ...e 7 inch diameter alu minum flexible liner to the fireplace Attach and seal the joints For optimum performance it is recommended that all horizontal runs have a inch rise per foot For safe and proper...

Страница 14: ...me pattern and creat ing a more traditional appearance 1 Remove all obstructing obsta cles i e brick panels logs etc 2 Remove the baffle plate from the rear wall of the firebox exposing the two screws...

Страница 15: ...d wall position the framework to accomodate the thickness of the finished wall MAINTAIN THESE MINIMUM CLEARANCES TO COM BUSTIBLES Fireplace framing 0 to stand offs top rear sides Fireplace finishing 3...

Страница 16: ...the hinge screen into place and with the control door open secure to the firebox using three screws Remove the pro tective plastic wrap from the louvres and install as illus trated Clip each upper lo...

Страница 17: ...he louvre tabs into the slots located at the top left and right corners of the unit A CLIPS CENTRE SLOT FLANGE SLOT TAB B C HINGE CLIP SLOT Before installing the logs you must first remove the log shi...

Страница 18: ...be necessary however to install the fibre baffle on top of the side and rear panels Charcoal provided should be randomly placed in the trian gular trays on either side of the of the burner Log colour...

Страница 19: ...he four screws that secure the lens frame This frame retains the glass lens The lamp can now be accessed Note Note Note Note Note Do not handle the lamp bulb with bare fingers Do not handle the lamp b...

Страница 20: ...ng contact with any mo mo mo mo moving or hot objects ving or hot objects ving or hot objects ving or hot objects ving or hot objects Drywall dust will penetrate into the blower bearings Drywall dust...

Страница 21: ...ng Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire de partment WARNING The gas valve has an inter...

Страница 22: ...obstructed 1 In order to properly clean the burner and pilot assem bly remove the logs to expose both assemblies 2 Keep the control compartment logs burner air shut ter opening and the area surroundi...

Страница 23: ...LOUVRE KIT BLACK 59 GDLVG UPPER LOWER LOUVRE KIT GOLD 60 L38K LOUVRE KIT UPPER LOWER BLACK 60 L38AB LOUVRE KIT UPPER LOWER ANTIQUE BRASS 60 L38PB LOUVRE KIT UPPER LOWER POLISHED BRASS 60 L38SS LOUVRE...

Страница 24: ...24 W415 0434 C 03 24 05 WARNING This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd...

Страница 25: ...me pattern around the thermocouple Pilot flame is not engulfing the thermocouple Thermocouple shorting faulty loosen and tighten thermocouple clean thermocouple and valve connection replace thermocoup...

Страница 26: ...sulation is broken or frayed replace the electrode if the ceramic insulator is cracked or broken replace the push button ignitor No spark at pilot burner fill the tank Out of propane gas Spark gap is...

Страница 27: ...27 W415 0434 C 03 24 05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns Dealer Name...

Страница 28: ...28 W415 0434 C 03 24 05 NOTES...

Отзывы: