Do not use this space heater in an 
explosive atmosphere. Keep heater away 
from areas where gasoline or other 
flammable liquids or vapors are stored. 

 

Prior to use, check for damaged parts     
such as hoses regulators, pilot or burner. 

 

Do  not attempt to alter unit in any 
manner. EXAMPLE: using the heater 
without the top canopy reflector or 
radiant screen. Do not shorten the burner 
post assembly. 

 

Heater must always be placed on a solid 
and level surface. 

 

Always maintain proper clearance to 
combustible materials.(Top 36

"

 Side

 

36

"

 

Always assure there is ample fresh air 
ventilation for outdoors use ONLY. 

 

Never replace or substitute the regulator 
with any regulator other than the factory 
suggested replacement. 

 

Do not clean heater with cleaners that are 
combustible or corrosive. 

 

Do not paint radiant screen, control panel 
or top canopy reflector. 

 

All leak test should be done with a soapy 
solution.  NEVER USE AN OPEN 
FLAME TO CHECK FOR LEAKS. 

 

The LP tank should be turned off when 
the heater is not in use. 

 

At least once a year, the unit should be 
inspected for the presence of spiders, 
spider webs or other insects. The burner 
area is a common spider haven and can 
damage the heater and render it unsafe 
for use, Check the heater immediately if 
any of the following exists: 

1.

 

The smell of gas in conjunction with 

extreme yellow tipping of the burner 
flames. 

 
 
 

 
 

2. The heater does not reach temperature. 
3. The burner makes popping noise during 

use (a slight popping noise is normal 
when the burner is extinguished). 

 

The LP regulator/hose assembly shall be 
located out of pathways where people 
may trip over it or in area where the hose 
will not be subject to accidental damage. 

 

Children and adults should be aware of 
hazards of high surface temperature and 
shall stay away to avoid burns of 
clothing ignition. 

 

Young children should be carefully 
supervised when they are in the area of 
the heater. 

 

Clothing or other flammable material 
should not be hung from the heater, or 
placed on or near the heater. 

 

Any guard or other protective device 
removed for servicing the heater must be 
replaced prior to operating the heater. 

 

Installation and repair should be done by 
a qualified service person, the heater 
must be should be inspected before use 
and at least annually by a qualified 
service person.    More frequent cleaning 
may be required as necessary. It is 
imperative that control compartment, 
burner and circulating air passageways 
of the heater be kept clean. 

 

Keep the appliance area clear and out of 
combustion material, gasoline and other 
flammable vapors and liquids. 

 

Do not obstruct the flow of combustion 
and ventilation air. 

 

Keep the ventilation opening of the 
cylinder enclosure free and clear of 
debris.

PRECAUTIONS 

NOTE: PLEASE READ THE FOLLOWING SAFETY

 

 

   Page 3 

Содержание PTH-103-3G

Страница 1: ...URNER REMOVAL 16 TROUBLE SHOOTING 17 PARTS LIST 18 WARRANTY 19 READ THE FOLLOWING INSTRUCTIONS CAREFULLY AND BE SURE YOUR PATIO HEATER IS PROPERLY INSTALLED ASSEMBLIED AND CARED FOR FAILURE TO FOLLOW...

Страница 2: ...read the installation operation maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY If you smell gas Shut off gas to appliance Extinguish any open flame I...

Страница 3: ...with Hose 1 Weighted Base Assembly 1 Hardware Package Leg Bracket 3 8 Nut 3 Leg Bracket 3 8 Flat Washer 3 Leg Bracket 3 8 Split Lock 3 Post Socket 3 8 Hexagon Screw 6 Post Socket 3 8 Flat Washer 6 Pos...

Страница 4: ...ll of gas in conjunction with extreme yellow tipping of the burner flames 2 The heater does not reach temperature 3 The burner makes popping noise during use a slight popping noise is normal when the...

Страница 5: ......

Страница 6: ...Heaters Please follow these easy steps to assembly your heater ASSEMBLY INSTRUCTION Page 4 Step 1 Weighted Base Place weighted base on work table for assembly of parts Step 2 Attach Leg Bracket Attach...

Страница 7: ...t lock and six 3 8 nut After you have parts assembly and properly lined up tighten top and bottom nut and bolts upward with a wrench STEP 3 STEP 4 STEP 4 Secure Tank Enclosure Secure two pieces tank e...

Страница 8: ...ASSEMBLY INSTRUCTION STEP 6 Secure The Post Connect post on with three of 3 16 flat head screw Page 6 Step 6 STEP 5 Step 5 Tank Cage Slide tank cage over base bracket...

Страница 9: ...mitter top It screws on threaded stud screwed onto emitter top Insert gas hose through post Attach the post on to heater head with four of 3 16 truss head screw STEP 7 Attach Reflector Combine three p...

Страница 10: ...resting on bracket Secure LP tank between brackets Intake Pipe Hose Assy STEP 10 Attach Regulator Attach flare adapter on hose end of the regulator assembly to the flare fitting on the intake hose Se...

Страница 11: ...mbly for hook up t o a s tandard A dented rusted or damaged propane tank may be hazardous and should be checked by your tank supplier Never use a propane tank with a damaged valve connection The propa...

Страница 12: ...ht and then take a 1 2 turn with the adjustable wrench NOTE The remaining connections are to be tested after the heater has been lit STEP 2 4 Intake hose fitting at the bottom of safety control valve...

Страница 13: ...form to local codes or in the absence of local codes with the standard for the storage and handling of liquid petroleum gases In the US use ANSI NFPA58 on National Fuel Gas Code ANSI Z223 1998 In Cana...

Страница 14: ...nd hose connections D Push and turn the gas control knob to PILOT position The igniter will spark at the same time Firmly pressed down the knob for 15 seconds until the pilot remain lit It might need...

Страница 15: ...rned off immediately the heater should not be operated again until repairs are made FIGURE 2 NORMAL FLAME POSITION RELIGHTING A Turn the control knob to off position B Wait five 5 minutes before attem...

Страница 16: ...safety control valve cylinder valve panel or instruction plate on post The posts of the burner must remain clean so that the gas flow is unrestricted The air inlet of the venturi tube must also be kep...

Страница 17: ...ot heat up enough for the main burner to come on If this occurs it will be necessary to clean the pilot BEWARE OF SPIDERS CAUTION BURNER TUBES MUST BE INSPECTED AND CLEANED BEFORE FIRST USE Spiders an...

Страница 18: ...n and remove the nut at the base of the pilot 4 Inspect the pilot and tubing for blockage you should be able to see through the pilot If it is obstructed by debris clear with a piece of wire 5 The cap...

Страница 19: ...nnection loose at gas control or damaged Pilot flame not touching the thermocouple Low gas pressure Blockage in burner orifice Control knob not in ON position Purge gas line and repeat ignition operat...

Страница 20: ...trol Housing Pilot Assembly Gas Valve Control Housing Front Panel Lighting Instruction Plate Logo Plate Valve Control Knob Coltrol Husing Base Post Gas Hose Tank Cover Post Socket Plate Tank Enclosure...

Страница 21: ...of parts damage resulting from any of the following negligent use or misuse of the product use on improper fuel gas supply use contrary to operating instructions or alteration by any person other than...

Отзывы: