general information
1.5 dimensions
This appliance must be recessed into a vented non-combustible wood-burning appliance (prefabricated or
masonry) only. The minimum appliance opening size in which the appliance is to be installed is:
HEIGHT 24 3/4" (62.8cm) WIDTH 34 5/16" (87.1cm) DEPTH 18 1/4" (46.3cm)
The minimum allowable chimney flue size is 6" (152mm) round.
The minimum distance, from the bottom of a combustible mantel projecting 3" (76mm) maximum from the wall to
the top of the appliance, is 12" (30.5cm) (see "minimum mantel clearances" section).
1.6 minimum clearance to combustibles
24 9
16 "
624mm
17 34 "
34 18 "
3"
2 PLS
16 12 "
8 1
16 "
23 11
16 "
GDIX4
[601mm]
[419mm]
[204mm]
[76mm]
[450mm]
[867mm]
SAFETY
BARRIER
front view
side view
top view
A non-combustible hearth must protrude a minimum of 12" (30.5cm) from the appliance.
note:
A combustible hearth may be used if the appliance is raised 4" (102mm) above the hearth or if a Wolf Steel
raiser box is installed.
note: